TPD/VPD Series - Getting Started v.1.0.5
Page 46
Copyright@ 2012 ICP DAS CO., LTD. All Rights Reserved. E-mail: [email protected]
b.
In the designer window, select the “Coil” item and then click the “F5” button or press
“F5” on your keyboard to add a new Coil, as per the picture below.
Step 3: Assign the variables.
a.
In the designer window, double click the “Normal Open Switch” item and select
the variable “V1” from the “Name” field in the “Select Variable” dialog box.
b.
Repeat the procedure to assign variables to the coils (I_7055_1_DO0/DO1).
Step 4: Change the “Type” for both the switches and the coils.
a.
In the designer window, select the “V1 Switch” item and click the “Space [T]” button
(or press either the “Space bar” or “P” on the keyboard) to switch the “Type” to
“Positive (P)”.
Normal Open Switch
Coil