TPD/VPD Series - Getting Started v.1.0.5
Page 40
Copyright@ 2012 ICP DAS CO., LTD. All Rights Reserved. E-mail: [email protected]
d.
Select the “TagName” browse button to enter the “Select variable” window. Click
“Scope” to set the I/O Tag (This demo uses I-7018Z
AI
ch0).
e.
Repeat the previous steps, and select the “Label” component from the “Toolbox”
panel, draw a rectangle, edit its font and outline color properties, etc. in the
“Properties Inspector” panel and assign a “TagName” (This demo uses I-7018Z
AI
ch0).
Step 6: Set up the communication detectors. (This demo uses I-7055D and I-7018Z)
a.
As shown in the picture below, select two types of
“Libraries”.
b.
Select and drag the “I_7055_1_ERROR” and “I_7018Z_2_ERROR” items from the
Workspace panel into the frame. (The light will turn on if there are any
communication problems between the TouchPAD and the I/O modules.)
Step 7: Set up the button to switch frames.
a.
From the “Layout” menu, select the “New Frame” option and then check the “[2]
SoftPLC” radio button and click “OK” to create a new LD frame.
a.
b.
a.
b.