4.
Create log file on the hour
.
The time interval for creating a new log file in MDCL is synchronized to 24 hour time. Depending
on the setting of maximum logging period, a new log file would be created at every interval on
the hour starting at midnight (00:00:00).
For instance, setting the maximum logging period to 6 hour means that new files would be create
to record data at 00:00:00, 06:00:00, 12:00:00, 18:00:00, and repeat that schedule.
If three MDCL modules are enabled to log data with different starting time and the same
Maximum Logging Period of 6 hour is applied, the log files will seem to start logging at the same
time among these devices, except the first time.
In conclusion, when you retrieve a large amount of files from multiple MDCL modules with the same
Logging Rate and Maximum Logging Period settings, you can easily complete the data synchroniza-
tion by modifying the prefix “T_” in the file name based on where these files were collected from.