ISaGRAF WinCE ViewPAC User Manual , V.1.6 , 1/2017 by ICP DAS
14
Soft-GRAF HMI
Provide support for the Soft-GRAF HMI. The user can design the HMI screen using the
Soft-GRAF Studio on the PC and then download it to the PAC to display the HMI on the PAC.
(
Optional I/O Functions (Refer to the ISaGRAF PAC I/O Selection Guide for I/O Module list)
PWM
Output
High Speed
PWM
Module
I-7088, I-8088W, I-87088W: 8-ch. PWM outputs, software support 1 Hz~100 kHz
(non-continuous), duty: 0.1~99.9%
DO
Module as
PWM
8-ch. max. 250 Hz max. For Off=2 & On=2 ms. Output square curve: Off: 2 ~ 32766 ms, On: 2
~ 32766 ms.
Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W,
8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate
fast square wave)
Counter,
Encod
er, Fre
quency
Parallel DI
Counter
8-ch. max. For 1 controller. Counter val: 32-bit. 250 Hz max. Min. ON & OFF width must > 2
ms.
Optional DI boards: I-8040W, 8040PW, 8042W, 8046W, 8048W, 8050W, 8051W, 8052W,
8053W, 8053PW, 8054W, 8055W, 8058W, 8063W.
Serial DI
Counter
Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16-bit)
Optional serial I-87K DI boards: I-87040W, 87046W, 87051W, 87052W, 87053W,
87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W.
Remote DI
Counter
All remote I-7K/I-87K DI modules support counters. 100 Hz max. Value: 0 ~ 65535
High Speed
Counter
I-87082W: 100 kHz max., 32-bit; I-8084W: 250 kHz max., 32-bit
Encoder
I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4 MHz for
pulse/direction and cw/ccw input mode. (
I-8084W: 250 kHz max., 4-ch encoder, pulse/direction or up/down or A/B phase (Quad.
mode), Not support Encoder Z-index. (
Frequency
I-87082W: 2-ch, 1 Hz ~ 100 kHz; I-87088W: 8-ch, 0.1 Hz ~ 500 kHz; I-8084W: 8-ch, 1 Hz ~
250 kHz;
Motion
Motion
Control
one I-8091W (2-axis) or two I-8091W (4-axis) can do motion control. only one I-8091W can
do X-Y dependent motion.
Port
Second
Ethernet
VP-2xW7/2xW6/4137 can add one optional I-8135W card in its slot 0 ~ 2 to expand the
second Ethernet port.
* Note: The COM5 ~ COM14 ports are located in the expansion boards if they are installed in slots 0~2 of
VP-2xW7/4xx7.
* ISaGRAF FAQ:
www.icpdas.com > Support > FAQ > ISaGRAF Soft-Logic PAC
*
ICP DAS recommends using
Industrial Ethernet Switches.
Содержание ISaGRAF VP-23W7
Страница 44: ......
Страница 118: ......
Страница 134: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS 9 2 On line help of ICP DAS add on functions function blocks ...
Страница 176: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 16 Appendix C Hardware Interface Dimension ...
Страница 177: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 17 VP 23W7 23W6 Unit mm ...
Страница 178: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 18 VP 25W7 25W6 Unit mm ...
Страница 179: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 19 ...
Страница 180: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 20 VP 41x7 41x6 Unit mm ...
Страница 185: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 25 ...