ISaGRAF WinCE ViewPAC User Manual , V.1.6 , 1/2017 by ICP DAS
9-5
Project Name
Description
I/O Boards Used
vpdmo_08
PID control, refer to VP-25W7/23W7 CD:
\napdos\isagraf\vp-25w7-23w7\english-manu\ "PID_AL...htm"
vpdmo_09
Store & backup boolean & long integer value To/From files
vpdmo_10
Store & backup boolean & long integer value To/From EEPROM
vpdmo_11
Dir is \Micro_SD ,save 3 values to 3 files per 10 minutes ,change
file name per month
vpdmo_14
Retain variable by Retain_b, Retain_N, Retain_f, Retain_t
(
-74)
vpdmo_16
Dir is \Micro_SD ,save 3 values to 1 file every minute ,change file
name every day
vpdmo19
Send UDP String to PC when alarm happens
(using variable array),Time_Gap is 1 sec
(Chapter 19.2 of the “ISaGRAF User's Manual” )
slot0: I-87055W
vpdmo19a
Send UDP String to PC 3 sec later, Time_Gap is 250ms
(Chapter 19.2 of the “ISaGRAF User's Manual” )
slot0: I-87055W
vpdmo19b
Send UDP Str to PC 3 sec later (vpdmo19a is better), Time_Gap
is 250 ms
(Chapter 19.2 of the “ISaGRAF User's Manual” )
slot0: I-87055W
vpdmo_20
receive String coming from remote PC or controller via UDP/IP
vpdmo_21
using "com_MRTU" to disable/enable Modbus RTU slave port,
vpdmo_22
PWM I/O demo. (Pulse Width Modulation), minimum scale is
2ms for ViewPAC
slot 0: I-8055W
vpdmo_23
Send Time String to COM3:RS-232 every second by using
COMOPEN, COMSTR_W (
-59)
vpdmo_24
Send string to COM3 when alarm 1 to 8 happens
slot 0: I-87055W
vpdmo_26
To move some pulse at x-axis of I-8091W of slot 1 in VP-25W7
(Chapter 18 of “ISaGRAF User's Manual” )
slot 1: I-8091W
vpdmo_27
Motion x
(Chapter 18 of the “ISaGRAF User's Manual” )
slot 1: I-8091W
slot 2: I-8090W
vpdmo_28
Motion x-y
(Chapter 18 of the “ISaGRAF User's Manual” )
slot 1: I-8091W
slot 2: I-8090W
vpdmo_29
Moving to the Abs. position when CMD is given
(Chapter 18 of the “ISaGRAF User's Manual” )
slot 1: I-8091W
slot 2: I-8090W
vpdmo_30
VP-25W7 (10.0.0.102) link two i8KE8 + I/O ,
one is 10.0.0.108, one is 10.0.0.109 (
-42)
vpdmo_31
VP-25W7 (10.0.0.2) link one i8Ke8 + I/O (10.0.0.109)
(
-42)
vpdmo_32
Set up VP-25W7 as TCP/IP Client & link to other TCP/IP server (1 slot 0: I-87055W
Содержание ISaGRAF VP-23W7
Страница 44: ......
Страница 118: ......
Страница 134: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS 9 2 On line help of ICP DAS add on functions function blocks ...
Страница 176: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 16 Appendix C Hardware Interface Dimension ...
Страница 177: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 17 VP 23W7 23W6 Unit mm ...
Страница 178: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 18 VP 25W7 25W6 Unit mm ...
Страница 179: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 19 ...
Страница 180: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 20 VP 41x7 41x6 Unit mm ...
Страница 185: ...ISaGRAF WinCE ViewPAC User Manual V 1 6 1 2017 by ICP DAS Ap 25 ...