56
3.15.5 loop-protect tx-mode
Description
Loop protection actively generate PDUs
Syntax
loop-protect tx-mode
Parameter
3.16 LLDP Configure commands
3.16.1 lldp holdtime
Description
Sets LLDP hold time (The neighbor switch will discarded the LLDP
information after \"hold time\" multiplied with \"timer\" seconds ).
Syntax
lldp holdtime <2-10>
Parameter
Name
Description
<2-10>
Holdtime 2-10 seconds
3.16.2 lldp receive
Description
Enable/Disable decoding of received LLDP frames.
Syntax
lldp receive
3.16.3 lldp reinit <1-10>
Description
LLDP tx reinitialization delay in seconds.
Syntax
lldp reinit <1-10>
Parameter
Name
Description
<1-10>
Reinitialization delay time
3.16.4 lldp timer <5-32768>
Description
Sets LLDP TX interval (The time between each LLDP frame transmitted
in seconds).
Syntax
lldp timer <5-32768>
Parameter
Name
Description
<5-32768>
5-32768 seconds.
3.16.5 lldp tlv-select
Description
Which optional TLVs to transmit.
Syntax
lldp
tlv-select
{
management-address
|
port-description
|
system-capabilities | system-description | system-name }
Parameter
Name
Description
management-address Enable/Disable transmission of management
address
port-description
Enable/Disable transmission of port description
system-capabilities
Enable/Disable transmission of system
capabilities
system-description
Enable/Disable transmission of system
description
system-name
Enable/Disable transmission of system name.