Index
(hex)
Name
Description
Data type
Flags
Default
zero
70n1:02
Reset extern latch value
Set the extern latch
value to zero
By setting this
Boolean from FALSE
to TRUE the extern
latch value (60n1:01)
will be set to zero
BOOLEAN
RO
FALSE
Index 0x70n2 Compare Outputs Ch.n
Index
(hex)
Name
Description
Data type
Flags
Default
70n2:0
Compare Outputs Ch.n
UINT8
RO
0x08
70n2:01
Enable compare
Enable the compare
output trigger function
By setting this
Boolean from FALSE
to TRUE the
compare function
will be enabled
By setting this
variable to FALSE the
extern latch function
will be disabled
It is suggested to first
set all the compare
parameters
(70n2:02, 70n2:07,
70n2:08) before
enabling the
compare trigger
function
If the counter has
been set to zero
while the compare
function is active,
then the compare
function has to be
first disabled and
then again enabled
in order for the
compare value to be
reset
BOOLEAN
RO
FALSE
70n2:02
Set auto increment compare
direction
Set the auto-
incremental direction
for the compare value
0 - positive direction
1- negative direction
BOOLEAN
RO
FALSE
70n2:07
Set first compare position
The first compare
INT32
RO
0
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
66
Содержание ECAT-2092T
Страница 3: ...Revision Revision Date Description Author 1 18 02 2019 Initial version M K...
Страница 9: ...1 4 Dimensions Figure 1 Dimensions of the ECAT 2092T ICP DAS Page ECAT 2092T User Manual Version 1 0 9...
Страница 50: ...Table 23 Resetting latch register procedure ICP DAS Page ECAT 2092T User Manual Version 1 0 50...
Страница 55: ...Step 5 Set the ECAT 2092T back into OP mode ICP DAS Page ECAT 2092T User Manual Version 1 0 55...
Страница 70: ......