Figure 30: Polarity change of input signal "A" inverts the counting direction
7.1.2.2Extern Latch Input Signal
The polarity of the extern latch signal (HR) indicates whether a falling or rising edge will
trigger a position latch or clear encoder counter action. The latch trigger edge has to be
set as follows:
Rising edge -->Active high
Falling edge --> Active low
The trigger level of the extern latch signal has to be set via CoE (0x80n0:05, n= 0;1).
NOTE: The trigger level for extern latch can not be set for each channel individually. Both
channel need to be set to the same trigger level.
7.1.3 Extern Latch Mode
Two latch modes are being supported (Table 8):
Latch current encoder position
Reset encoder counter to zero
Latch Mode
Description
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
39