For each channel the following configuration procedure has to be done:
-
Counting mode setting
-
A/B/C signal polarity setting. The input signal may be active low or active high.
-
Low pass filter clock cycle setting
-
For external latch (if selected):
External latch HR signal polarity setting: The input signal may be active low
(falling edge trigger) or active high (rising edge trigger).
NOTE: The HR signal polarity can not be set for each channel individually. Both
channel need to be set to the same polarity.
Extern latch mode setting: An latch signal can either latch the counter value or
set the counter value to zero
-
For compare trigger (if selected):
The pulse width setting of the triggered DO signal.
Example of setting the encoder counting mode for each channel:
Step 1:
Go to "ENC Setting Ch.0" of a channel. Extend the index tree and double click
"Counting mode" with the index 8000:09 for channel 0.
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
30