The setting of the sync manager for the output and input data is available at the TwinCAT
"CoE online" tab.
Figure 20: SyncManager 2 parameters
SyncManager parameter description (time unit: nanosecond):
Calc and Copy Time (0x1C32.6 / 0x1C33.6): Required time to copy the process data
from the ESC to the local memory and calculate the output value.
Delay Time (0x1C32.9 / 0x1C33.9): Delay from receiving the trigger to set the output
or latch the input.
Cycle Time (0x1C32.2 / 0x1C33.2 ): The current cycle time for the application. When
using DC synchronization the value is read from register 0x9A0:0x9A3.
0x1C32.5 / 0x1C33.5 (Min Cycle Time): Minimum cycle time for the application. It is
the total execution time of all slave application related operations.
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
26