ECAN-240-FD (Modbus TCP to 2-port CAN FD Gateway) User Manual
Version 1.0.0
Page
:
8
Copyright © 2022 ICP DAS Co., Ltd. All Rights Reserved E-mail: [email protected]
2. Hardware Information
This chapter provides a detailed description of the front panel, the hardware specifications and
the dimensions for the ECAN-240-FD module.
2.1. Specifications
CAN Bus Interface
Channels
2
Connector
9-pin D-sub male x 2
Transmission Speed
CAN bit rates: 10 ~ 1000 kbps,
CAN FD bit rates for data field: 100 ~ 10000 kbps
Terminal Resistor
DIP switch for the 12
0 Ω terminal resistor
Isolation
3 kV VDC for DC to DC, 2500 Vrms for photo couple
Specification
ISO 11898-2, CAN 2.0 A/B and FD
Ethernet Interface
Ethernet
10/100 Base-TX, 8-pin RJ-45 x 1, (Auto-negotiating, Auto-MDI/MDIX,
LED indicator)
Protocol
Modbus TCP, HTTP, BOOTP, TFTP
LED Indicators
Status
1 x Power status, 3 x CAN1 status, 3 x CAN2 status
Power
Power Supply
Unreg10 ~ +30 VDC
Power Consumption
0.05A @ 24V
DC
Mechanical
Installation
DIN-Rail
Casing
Metal
Dimension (mm)
122.0 x 160.0 x 28.0 (W x L x H)
Environment
Operating Temperature
-25 °C ~ +75 °C
Storage Temperature
-30 °C ~ +80 °C
Relative Humidity
10 ~ 90% RH, Non-condensing