CAN-8x23 user’s manual (Revision 3.20, Ma r/08/2012) ------
116
Transmission Type 0 for the first RxPDO
Step 12. Users can set the transmission type of the first RxPDO to 0.
11-bit COB-ID (bit)
RTR
Data
Length
8-byte Data (byte)
Func Code
Node ID
10 9 8 7 6 5 4 3 2 1 0
0
1
2
3
4
5
6
7
1
1 0 0 0 0 0 0 0 0 1
0
8
2F 00 14
02
00
00
00
00
SDO client
SDO server
(CAN-8x23)
ccs
:
1
n
:
3
e
:
1
s
:
1
m
:
00 14 02
d
:
00
11-bit COB-ID (bit)
RTR
Data
Length
8-byte Data (byte)
Func Code
Node ID
10 9 8 7 6 5 4 3 2 1 0
0
1
2
3
4
5
6
7
1
0 1 1 0 0 0 0 0 0 1
0
8
60 00 14
02
00
00
00
00
SDO client
SDO server
(CAN-8x23)
scs
:
3
m
:
00 14 02
Step 13. Change the DO value of the I-8057 to be 0x5678 by using the 1st
RxPDO.
11-bit COB-ID (bit)
RTR
Data
Length
8-byte Data (byte)
Func Code
Node ID
10 9 8 7 6 5 4 3 2 1 0
0
1
2
3
4
5
6
7
0
1 0 0 0 0 0 0 0 0 1
0
8
78 56 00
00
00
00
00
00
PDO
producer
PDO consumer
(CAN-8x23)
COB-ID
: 0x201
L
: 8
PDO-msg
: 78 56 00 00 00 00 00 00
Step 14. The DO value isn
’t changed immediately according to the character of
the transmission type 0. Meanwhile, the SYNC message is needed to trigger