Installation:
General Requirements:
Generally Turbos can be installed in much smaller spaces and much more easily than any comparable
equipment of similar cooling (or heating) capacity. Floor mounting is the simplest solution and this is included in the
standard price, however specially designed wall mounting or even ceiling mounting kits are available if required.
Ventilation Requirements:
Cold air is taken in from the front and the top of the unit, so these surfaces must be at least 200-300 mm from a wall
or obstruction. Hot air is expelled from the 2 long sides and these sides must be at least 200-300 mm from a wall
or obstruction. If installing more than one Turbo aligned to each other as shown in the illustration at
bottom left, they should be at least 500 mm apart. This spacing can be reduced if they are installed front to back as
shown in the illustration at bottom right.
Plumbing Requirements:
Just 2 standard 40mm PVC pool water pipes are required for each TurboCool/Spa installation for carrying water to
and from the spa. The TurboCool can be up to a maximum of 25 meters from the Spa Pool and it can be up to 5
meters above or below the Spa Pool, but naturally the closer it is in both distance and level the higher the efficiency
will be.
The two PVC water pipes must be insulated with standard 90-100mm diameter (4”) insulation lagging to prevent
energy loss.
Dimensions in Metric and Imperial:
630 mm 25 in
/
6
4
0
m
m
2
5
in
/
4
5
m
m
2
in
/
550 mm 22 in
/
6
3
0
m
m
2
5
in
/
550 mm 22 in
/
6
3
0
m
m
2
5
in
/
150 mm
5
0
m
m
2
in
/
Spa
Plumbing
50
mm
O.D.
Pipe
LEFT & RIGHT SIDE
FRONT
TOP
OU
T
IN
TurboCools Can be Conveniently Mounted on Floors , Walls or Ceilings:
iCool can provide special mounting brackets for most situations.