“Back 1”

 

You can flip forward or backwards from page to page using the BACK button on the 

right-hand side of the help screens or you can return to be main help menu page at any time by 
touching the HOME button.

 

“All Stop”

There are several ways to stop the system and close it down. 

1. You can stop the cooling system only by touching the 

“Stop System”

 button, in this case 

the pump will continue to run, 

2. You can stop to pump at any time by touching the 

“Stop pump”

button. Stopping the 

pump while the System is running also automatically stops the Cooling (or Heating) System 
because it can not run safely without water. 

3 .Alternatively you can stop everything by touching the 

”All Stop”

.button 

If you use the

”All Stop”

 button  the fans may continue to run for a short time to cool the cabinet.

Display the pool temperature at full screen size.

If you touch the number in the pool temperature window 
on the Main Operation Screen for a few seconds the 
screen will change to a full-screen display of the pool 
temperature. (shown here at right)
This is useful if you wish to monitor the system from a 
distance.
The pre-set temperature and the outside temperature 
continue to be displayed in smaller windows for your 
reference.To return to the main operating screen touch 
the 

BACK 1

 button.

14

10

25

Systems Preferences

Available System Preferences

Touching the 

“Home” 

button will take you to a screen that will give you access to the 

SYSTEMS SETTINGS

 that allow you to customise certain settings to your preference.

Optimum settings are automatically selected

 

so there is normally no need to use this 

feature.

Main Cooling Fan Speed 

This allows you to set the main cooling fans to either 

Normal

 or 

Quiet

 mode. Generally you should always leave it in the 

Normal

  

mode which is fully automatic and allows the system to control the 

fan speed to give the very best efficiency.

Temperature Display scale. 

This can be set to either Centigrade or Fahrenheit and changes all 
of the displays throughout the entire system. The iCool normally 
reads in Centigrade as this is the world standard. It can convert the 
display to ºF if required, however due to rounding off calculations 
between Cº and Fº there may be minor differnces in the Fº display, 
however the system always holds the water temperature to within 1ªC.

Sound Level.

The 

Sound level

 

adjusts the sounds made when touching the screen and by the alarms. Normally it should be left 

on high to assist with settings and to make sure alarms are heard. There are three settings High, Medium and Low.  
A red dot indicates which setting is selected in each of the available settings. 

Stop

Stop

Содержание Turbo Dual Temp

Страница 1: ...Installation Operation Manual Turbo Cool Turbo Dual Temp 2012 Models ...

Страница 2: ...Connections Page 9 Installing the Pump Page 9 Operating your TurboCool in Cold Mode Pages 10 to 12 Operating your TurboCool in Heat Mode Page 12 Detailed Function Description Page 13 Setting System Preferences Page 14 Timers and Clock Pages 15 to 16 Locking the Touch Screen Page 16 Digital Power Management Page 16 Trouble Shooting Page 17 Specifications Page 18 Contents ...

Страница 3: ...ularly The main power switch is also part of the electrical safety circuit that can prevent the possibility of electric shock It is essential to test this safety system each time you use the iCool to make certain it is operating correctly This takes only a few seconds To Test the Earth Leakage Safety Device Turn on the main switch and then press the test button on the switch body If the safety sys...

Страница 4: ... your spa pool is level with or above the pump then there is generally no need to prime the system as the water will flow by gravity to the pump If water does not flow after more than 2 minutes the iCool will shut down to protect the pump against over heating If your pump has a lint basket please ensure that it clean and that it is full of water before starting the pump If the water does not begin...

Страница 5: ...gher and restart Normally settings above 8ºC or or 45ºF will not freeze the tanks in any conditions Safe Temperature Settings Following international safety reccomendations your iCool will not accept water temperature settings below 5ºC or 40ºF as this would put athletes using the system at risk of hypothermia The tanks can only freeze if your setting is below 7 to 8ºC and this can only happen in ...

Страница 6: ...special connection to 3 phase power whereas the TurboCool only requires single phase power This is new technology developed by iCool and has many advantages The Intelligent Control System Saves a Lot of Electricity Firstly start up current is much lower because the built in digital control makes sure that the 2 systems never start at exactly the same time so it never exceeds the rating of a normal...

Страница 7: ...be at least 500 mm apart This spacing can be reduced if they are installed front to back as shown in the illustration at bottom right Plumbing Requirements Just 2 standard 40mm PVC pool water pipes are required for each TurboCool Spa installation for carrying water to and from the spa The TurboCool can be up to a maximum of 25 meters from the Spa Pool and it can be up to 5 meters above or below th...

Страница 8: ...cables that you must unplug in order to mount the back panel to a wall STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel STEP 4 The rear panel has several holes that can be used for screwing to a wall Select a good position where the screen can be easily reached by operators and can be seen from the recovery spa STEP 5 Replace the 3 plugs as shown Push the ...

Страница 9: ...ect your TurboCool is to a wall box with an isolation switch however because the iCool also has an isolation safety switch and an earth leakage safety device built in you can also simply attach a power plug and plug that into a standard wall socket Connecting the Pump Depending on your order on the rear of your TurboCool there will either be a standard AC power socket or a splash proof connection ...

Страница 10: ...take about 20 seconds and the screen will be black for about 10 seconds Touch the WELCOME screen anywhere and the Main Operating Screen will appear The status bar will flash white while the software loads and the system is checked The STATUS LIGHTS bar above the touch screen will change colour or flash to give a clear indication of each function While the software is loading the system conducts an...

Страница 11: ...ature Selection Screen and accepted 15ºC then you will still be seeing the Main Operating Screen NOTE The temperatures can also be displayed in Fahrenheit This is explained on page 14 of this Manual STEP 3 Start the Water Pump Touch the Start Pump button The pump will begin operating and water should begin circulating within a minute or so Please note When you touch the main buttons they change fr...

Страница 12: ...AT Do not operate the HEAT COLD switch while the iCool is running Turn off the main power first then change the switch position and turn the main power back on In HEAT mode the fans will immediately lock on to medium speed which is the most efficient setting for heating A green light on the bottom right hand of the Turbo cabinet will light to indicate that heating mode reverse cycle is selected In...

Страница 13: ...hing the Change Setting button this will take you to the Change Settings Screen From here you proceed as described on page 11 Lights Some iCool models have convenient area lighting which is very helpful if the area around your installation is not well lit Touching the Lights button takes you to a simple screen that has both ON and OFF light buttons When you touch the ON button the area lights illu...

Страница 14: ...reference To return to the main operating screen touch the BACK 1 button 14 10 25 Systems Preferences Available System Preferences Touching the Home button will take you to a screen that will give you access to the SYSTEMS SETTINGS that allow you to customise certain settings to your preference Optimum settings are automatically selected so there is normally no need to use this feature Main Coolin...

Страница 15: ...n screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool and outside temperature will also be displayed The count down can be set for once only or it can repeat automatically as many times as you like This is particularly convenient if you have a number of athletes using the same pool at the same time ...

Страница 16: ...horised operators iCool Systems have attractive user interfaces this makes them easy to use but the downside is that untrained people often like to play with the colourful touchscreens This can upset all your settings and even cause an unintended shutdown To lock the screen so that no further inputs can be made touch and hold the iCool icon on the main run screen for more than 10 seconds you can o...

Страница 17: ...explanation and advice on how to correct this If the iCool shuts down and displays a System Too Hot Red Warning Screen Your TurboCool is very powerful and can remove as much as 10 000 watts of heat per hour from your pool Naturally this heat has to be removed into the air surrounding the system The powerful internal fans can normally handle this with ease however if the air flow around the iCool i...

Страница 18: ...er Management System Digital 4 parameter Digital 4 parameter Standard Mounting Available Mounting Options Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Area Lighting Built In 10 Watts 10 Watts Standard User Control and Information System Colour Touch Screen High Resolution LCD Colour Touch Screen High Resolution LCD Electrical...

Отзывы: