Product Discription:

Designed Especially For Athlete Recovery Therapy and With Higher Power Efficiency 

Than Any Comparable Product:

iCools have become the most popular and widely used ice bath cooling and heating systems in the world for the 

economic and efficient provision of accurate automatic temperature control for modern ice bath recovery therapy 

for athletes.

Designed and manufactured especially for large ice bath recovery and contrast therapy spas and pools, the 

TurboCool model  provides up to 10,000 watts of cooling (or heating) at the highest power efficiency available. It is 

a high technology twin heat pump in a very compact single package, with 2 compressors and 2 heat exchangers in 
separate circuits controlled by a digital power management system to minimise electricity use. The entire system 
is fully automatic and is controlled and monitored via a modern colour touch screen user interface driving an 
advanced digital controller.

Lowest Running Cost:

Using the latest heat pump technology the TurboCool can produce up to 10,000 watts of water chilling power yet  it 
uses only a maximum of 3000 watts in normal operation to do so. Furthermore, because the TurboCool is actually 
two 5000 watt heat pumps in a single cabinet it can can operate from a normal 15 amp power outlet (220v models), 
by digitally controlling the compressor starting sequences to avoid high startup loads. The built in Intelligent Digital 
Power Management System, DPMS, (exclusive to iCool) means that your TurboCool can operate from a normal 15 
amp power outlet if necessary. (30 Amps @ 110V in North America and Japan). This saves a lot of money on initial 
installation costs, because most other chillers of this power need a special connection to 3 phase power, whereas 
the TurboCool only requires single phase power. 

This is new technology developed by iCool and has many advantages.   

The Intelligent Control System Saves a Lot of Electricity.

Firstly, start up current is much lower because the built in digital control makes sure that the 2 systems never start 
at exactly the same time, so it never exceeds the rating of a normal single phase power socket. 
The second advantage is that the TurboCool can acurately provide the exact amount of cooling power actually 
required to avoid waste. Both of the twin heat pumps run at full power for fast cooling, but at other times such as 
over night and when the spa pool is not in heavy use, it automatically reduces power or even turns one of the heat 
pumps off and that saves a lot of electricity. Only iCool has this power saving feature.

In Heating Mode Running Cost can be up to 65% Lower Than Typical Spa Heaters. 

In  

heating mode (ICTurbo DualTemp model) the Turbo uses as much as 65% less electricity compared to a normal 
electric element spa water heater, because it uses modern reverse cycle heat pump technology. It does not use 
wasteful electric elements. So with power saving features in both cooling and heating modes the owner can save 
a lot of money each year on electricity costs. 

Standard Package Includes:

A Full Colour Touch Screen to control and monitor all functions.
(On request the touch screen can also display your club logo or graphics.)
Dual Titanium Heat Exchanger Tanks.
Simple industry standard connections for water In and water out.
Twin digitally controlled heat pump cooling systems in a single cabinet. 
Enviromently friendly Eco Refrigeration Gas HR22 “Green Gas”.
Vibration isolation mountings.
Built in earth leak detection safety system.
Area Lighting controlled from the touch screen.

*As optional extra, 

a very convenient Wall Mounted Remote Control Touch Screen Panel is available. 

Содержание Turbo Dual Temp

Страница 1: ...Installation Operation Manual Turbo Cool Turbo Dual Temp 2012 Models ...

Страница 2: ...Connections Page 9 Installing the Pump Page 9 Operating your TurboCool in Cold Mode Pages 10 to 12 Operating your TurboCool in Heat Mode Page 12 Detailed Function Description Page 13 Setting System Preferences Page 14 Timers and Clock Pages 15 to 16 Locking the Touch Screen Page 16 Digital Power Management Page 16 Trouble Shooting Page 17 Specifications Page 18 Contents ...

Страница 3: ...ularly The main power switch is also part of the electrical safety circuit that can prevent the possibility of electric shock It is essential to test this safety system each time you use the iCool to make certain it is operating correctly This takes only a few seconds To Test the Earth Leakage Safety Device Turn on the main switch and then press the test button on the switch body If the safety sys...

Страница 4: ... your spa pool is level with or above the pump then there is generally no need to prime the system as the water will flow by gravity to the pump If water does not flow after more than 2 minutes the iCool will shut down to protect the pump against over heating If your pump has a lint basket please ensure that it clean and that it is full of water before starting the pump If the water does not begin...

Страница 5: ...gher and restart Normally settings above 8ºC or or 45ºF will not freeze the tanks in any conditions Safe Temperature Settings Following international safety reccomendations your iCool will not accept water temperature settings below 5ºC or 40ºF as this would put athletes using the system at risk of hypothermia The tanks can only freeze if your setting is below 7 to 8ºC and this can only happen in ...

Страница 6: ...special connection to 3 phase power whereas the TurboCool only requires single phase power This is new technology developed by iCool and has many advantages The Intelligent Control System Saves a Lot of Electricity Firstly start up current is much lower because the built in digital control makes sure that the 2 systems never start at exactly the same time so it never exceeds the rating of a normal...

Страница 7: ...be at least 500 mm apart This spacing can be reduced if they are installed front to back as shown in the illustration at bottom right Plumbing Requirements Just 2 standard 40mm PVC pool water pipes are required for each TurboCool Spa installation for carrying water to and from the spa The TurboCool can be up to a maximum of 25 meters from the Spa Pool and it can be up to 5 meters above or below th...

Страница 8: ...cables that you must unplug in order to mount the back panel to a wall STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel STEP 4 The rear panel has several holes that can be used for screwing to a wall Select a good position where the screen can be easily reached by operators and can be seen from the recovery spa STEP 5 Replace the 3 plugs as shown Push the ...

Страница 9: ...ect your TurboCool is to a wall box with an isolation switch however because the iCool also has an isolation safety switch and an earth leakage safety device built in you can also simply attach a power plug and plug that into a standard wall socket Connecting the Pump Depending on your order on the rear of your TurboCool there will either be a standard AC power socket or a splash proof connection ...

Страница 10: ...take about 20 seconds and the screen will be black for about 10 seconds Touch the WELCOME screen anywhere and the Main Operating Screen will appear The status bar will flash white while the software loads and the system is checked The STATUS LIGHTS bar above the touch screen will change colour or flash to give a clear indication of each function While the software is loading the system conducts an...

Страница 11: ...ature Selection Screen and accepted 15ºC then you will still be seeing the Main Operating Screen NOTE The temperatures can also be displayed in Fahrenheit This is explained on page 14 of this Manual STEP 3 Start the Water Pump Touch the Start Pump button The pump will begin operating and water should begin circulating within a minute or so Please note When you touch the main buttons they change fr...

Страница 12: ...AT Do not operate the HEAT COLD switch while the iCool is running Turn off the main power first then change the switch position and turn the main power back on In HEAT mode the fans will immediately lock on to medium speed which is the most efficient setting for heating A green light on the bottom right hand of the Turbo cabinet will light to indicate that heating mode reverse cycle is selected In...

Страница 13: ...hing the Change Setting button this will take you to the Change Settings Screen From here you proceed as described on page 11 Lights Some iCool models have convenient area lighting which is very helpful if the area around your installation is not well lit Touching the Lights button takes you to a simple screen that has both ON and OFF light buttons When you touch the ON button the area lights illu...

Страница 14: ...reference To return to the main operating screen touch the BACK 1 button 14 10 25 Systems Preferences Available System Preferences Touching the Home button will take you to a screen that will give you access to the SYSTEMS SETTINGS that allow you to customise certain settings to your preference Optimum settings are automatically selected so there is normally no need to use this feature Main Coolin...

Страница 15: ...n screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool and outside temperature will also be displayed The count down can be set for once only or it can repeat automatically as many times as you like This is particularly convenient if you have a number of athletes using the same pool at the same time ...

Страница 16: ...horised operators iCool Systems have attractive user interfaces this makes them easy to use but the downside is that untrained people often like to play with the colourful touchscreens This can upset all your settings and even cause an unintended shutdown To lock the screen so that no further inputs can be made touch and hold the iCool icon on the main run screen for more than 10 seconds you can o...

Страница 17: ...explanation and advice on how to correct this If the iCool shuts down and displays a System Too Hot Red Warning Screen Your TurboCool is very powerful and can remove as much as 10 000 watts of heat per hour from your pool Naturally this heat has to be removed into the air surrounding the system The powerful internal fans can normally handle this with ease however if the air flow around the iCool i...

Страница 18: ...er Management System Digital 4 parameter Digital 4 parameter Standard Mounting Available Mounting Options Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Area Lighting Built In 10 Watts 10 Watts Standard User Control and Information System Colour Touch Screen High Resolution LCD Colour Touch Screen High Resolution LCD Electrical...