When power is on, the flow meter will display 

Flow Rate

 / 

Net Totalizer

.

Signal quality & Time.

OPERATION

DISPLAY

STEPS

Main Display

Press           Key

Totalizer

SQ 99

Net

768.89 GAL

GPM

12:30:18

3.368

SQ 99

S.ToT

23.89 

GAL

GPM

12:30:18

3.368

Press          to Display 

Run time / Day Totalizer / Month Totalizer / Year Totalizer

Press          to Return to Previous Menu.

Press           Key

Press           Key

Flow Rate / S.TOT Totalizer

Press           Key

Flow Rate / Velocity / Net Totalizer

Press          to Display 

Flow Rate / S.TOT Totalizer

Press          to Return to Previous Menu.

Velocity / Net Totalizer

Press          to Display 

Velocity / Flow Rate / Net Totalizer

Press          to Return to Previous Menu.

Runtime

Year

GAL

Day

GAL

Mth.

GAL

216h

79.068
3839.8

3768

SQ 99

Net

GAL

f/s

GPM

Vel

Flow

12:30:18

1.068
3.339

768.89

Press          to Display 

Velocity / Net Totalizer,

Press          to Return to Previous Menu.

8

23-0

166

     © Icon Process Controls Ltd.

Display Description

Power on Main Display shows 

Flow Rate

 & 

Net Totalizer

OPERATION

DISPLAY

STEPS

Main Display

Press           Key

Setup Menu

Press          to Display 

Setup Menu

.

The following options are available (using the        or         Buttons)

0. Pipe parameter

1. System setting

2. Calibration

3. Output setting

4. History data

Setup menu

0. Pipe parameter

1. System setting

2. Calibration

3. Output setting

4. History data

Setup Menu

20-03-18

Net

768.89 

GAL

f/s

12:30

1.868

SQ 99

Net

768.89 GAL

GPM

12:30:18

3.368

UltraFlo

®

 UF-500

Clamp-On Ultrasonic Flow Meter Sensor

Содержание UltraFlo truflo UF-500 Series

Страница 1: ...s manual carefully before starting to use the unit Producer reserves the right to implement changes without prior notice UltraFlo UF 500 Series Operating Manual UltraFlo UF 500 Clamp On Ultrasonic Flo...

Страница 2: ...ns Powering ON Display Description Setup Menu Pipe Parameter Setup Menu System Setting Setup Menu Calibration Setup Menu Output Setting Setup Menu Data Logging Setup Menu Dimensions Installation Posit...

Страница 3: ...te or unintended use or modifications of the flow meter Conversions and or changes to the flow meter may only be made if they are expressly performed in accordance with the operating instructions in t...

Страница 4: ...isplay Wide Dynamic Flow Range of 0 3 to 15 ft s 0 1 to 5 m s High Accuracy 2 0 of Full Scale Pipe Sizes 4 Suitable for RO Systems Excellent External Corrosion Resistance Data Logging Exploded View Ch...

Страница 5: ...s are available Cubic Meters m3 Liters L US Gallons GAL hour min Default Unit Setting GPM Totalizer Six Bit Digit Liquid Water Sea water Oil Pipe Material Carbon Steel Stainless Steel PVC Copper PVDF...

Страница 6: ...ition the display over the Upper Bracket and connect using the mounting screws DO NOT over tighten Install Polycarbonate Cover Connect M12 Cable Wiring Diagram Pipe Lower Bracket Display 6 23 0166 Ico...

Страница 7: ...00 is the minimum signal could be detected and 99 represents the maximum Normally the transducer position should be adjusted repeatedly and coupling compound should be checked frequently until the si...

Страница 8: ...eturn to Previous Menu Runtime Year GAL Day GAL Mth GAL 216h 79 068 3839 8 3768 SQ 99 Net GAL f s GPM Vel Flow 12 30 18 1 068 3 339 768 89 Press to Display Velocity Net Totalizer Press to Return to Pr...

Страница 9: ...e using the or buttons 0 Pipe parameter 1 System setting 2 Calibration 3 Output setting Setup menu Press Select 1 System setting then to display The following options are available using the or button...

Страница 10: ...y value changes greatly damping can be set to adjust the measurement response speed of the product The unit is in seconds 9 Display format Display format 0 x 0 001 1 x 0 01 2 x 0 1 The display digit o...

Страница 11: ...n prevent that when the pump stops working and the liquid flows at a low speed in the pipe data accumulation error caused by continuous reading of flow meter Input is generally recommended 0 05f s as...

Страница 12: ...A value 15 00 GPM GPM Generally pipes made of SS304 or SS316 are with wall thickness of more than 2mm In practical use it will receive false signals due to the interference of pipe wall signals It is...

Страница 13: ...wing conditions the system alarm signals are being activated or the totalizer pulse is being transmitted Pulses are cumulative output and the equivalent of each pulse is 0 01L 100m3 It can be set thro...

Страница 14: ...Totalizer flow for months 2 By Year Display Totalizer flow for years History data 0 By Day 1 By Month 2 By Year 0 Pipe parameter 1 System setting 2 Calibration 3 Output setting 4 History data 14 23 01...

Страница 15: ...D Flow L 5D Flow L 10D Flow L 5D Flow L 10D Flow L 5D Flow L 10D Flow L 5D Flow L 10D Flow L 5D Source 90 Elbow Source 2 x 90 Elbow in One Plane Source 2 x 90 Elbow in Different Plane Source T Section...

Страница 16: ...16 23 0166 Icon Process Controls Ltd Installation Positions Flow L 10D Flow L 5D Flow L 10D Flow L 5D Source Diffuser Source Valve UltraFlo UF 500 Clamp On Ultrasonic Flow Meter Sensor...

Страница 17: ...d to electrical mechanical or chemical damage due to improper accidental or negligent use 3 Have been modified or altered 4 Anyone other than service personnel authorized by Icon have attempted to rep...

Страница 18: ......

Отзывы: