BIA-DPC3 rev 5
Page 41
8.6 Last five failure record
The control panel can memorize the last five failures of pump, so it is very convenient for the users to analyse the pump running
conditions.
Displaying the last five failure record.
Press the
MODE
key to switch to manual state, make sure the pump is not running and the LCD screen is displaying:
Hold pressing
A STOP
key and press
MODE
key, the control panel makes
a “beep” sound and displays
pump A failure record.
Press the
A STOP
key to quit the failure record display;
Note: the failure displayed above is PUMP STALLED.
Repeat for pump B by using
B STOP
key.
8.7 Pump accumulative running time
The control panel can memorise how many hours of pump running, so it is very convenient for the pump user to analyse the
pump running conditions and do maintenance.
Displaying the pump accumulative running time
.
Press the
MODE
key to switch to manual state, make sure that the pump is not running and the LCD screen is displaying:
Hold pressing the
STORE
key and press the
A STOP
key. The control panel makes a “beep” s
ound and displays the accumulative
run time.
Failure Icon
Содержание DPC3
Страница 1: ...BIA DPC3 rev 5 Page 1 Installation and Operation Manual DPC3 ...
Страница 23: ...BIA DPC3 rev 5 Page 23 3 2 3 Drainage by liquid level control through float switches or probes cont ...
Страница 30: ...BIA DPC3 rev 5 Page 30 5 2 2 Water supply by pressure control through pressure switch and tank cont ...
Страница 31: ...BIA DPC3 rev 5 Page 31 5 2 3 Water supply by pressure control through pressure switch and tank cont ...
Страница 35: ...BIA DPC3 rev 5 Page 35 6 2 2 Water supply by liquid level control through float switches or probes cont ...
Страница 45: ...BIA DPC3 rev 5 Page 45 ...
Страница 46: ...BIA DPC3 rev 5 Page 46 ...