73
2001 NEW
2001 NEW
7
DSC OPERATION
■
DSC Settings
D
Setting the 10 Second Delay
Select whether or not the transceiver automatically
switches to the displayed frequency 10 seconds after
receiving a DSC call.
By regulation, after receiving a DSC call, the
transceiver automatically switches the operating
channel to the displayed frequency. However,
when you set this function to "OFF", the transceiver
remains on the operating channel, even after
receiving a DSC call.
1. Push [MENU].
2. Select “10 Second Delay,” then push [ENT].
(DSC Settings >
10 Second Delay
)
3. Select an option, then push [ENT].
• On: When receiving a DSC call with a specified
frequency, the transceiver automatically switches
the operating channel to the displayed frequency.
(Default)
•
Off: The transceiver remains on the operating channel
until you push [Active]
to enter the DSC
Task mode.
4. Push [MENU] to return to the Main screen.
D
Setting the Alarm Status
Safety/Routine
Select whether or not to sound an alarm when
receiving the Safety or Routine DSC call.
1. Push [MENU].
2. Select an item, then push [ENT].
(DSC Settings > Alarm Status >
Safety
)
(DSC Settings > Alarm Status >
Routine
)
3. Select an option, then push [ENT].
•
On: Alarm sounds. (Default)
•
Off: Alarm does not sound.
4. Push [MENU] to return to the Main screen.
Warning
Select whether or not to sound an alarm:
•
When no MMSI code is entered.
•
When the position data has not been updated for
10 minutes.
•
When the position data has not been manually updated
for 4 hours.
•
After the invalid GPS position data or manually entered
position data has not updated for 23.5 hours.
1. Push [MENU].
2. Select “Warning,” then push [ENT].
(DSC Settings > Alarm Status >
Warning
)
3. Select an option, then push [ENT].
•
On: Alarm sounds. (Default)
•
Off: Alarm does not sound.
4. Push [MENU] to return to the Main screen.