6
MENU SCREEN
6-11
Acquisition
In the Digital mode (Trunking only)
Selects a number for the Control CH Acquisition
Parameter� The Acquisition Parameter determines
whether a site is out of the service range or not� (p� 7-16)
TIP:
The Control CH Retention Parameter is
programmed using the programming software� See
the softwareʼs Help file for details.
Call Back
In the Digital mode (Trunking only)
Turns the Call Back function ON or OFF�
The Call Back function automatically sends back an
acknowledgement (Call Back) to the caller station
after receiving an Individual call� (p� 7-21)
Retention
In the Digital mode (Trunking only)
Selects a number for the Control CH Retention
Parameter� The Retention Parameter determines
whether a site is within the service range or not� (p� 7-17)
TIP:
The Control CH Retention Parameter is
programmed using the programming software� See
the softwareʼs Help fi le for details.
Roaming Request
In the Digital mode (Trunking only)
Turns the Roaming Request function ON or OFF�
When this function is turned ON, the transceiver starts
a Roaming Scan, regardless of the error rate� (p� 7-18)
L
If the Site Lock function is turned ON, the transceiver
resumes a Roaming Scan when this function is turned
ON�
Site Select
In the Digital mode (Trunking only)
Displays the “Site Select” screen� Then, push [Up] or
[Down] to select a site� After selecting, push [OK] to
save� (p� 7-19)
Site Lock
In the Digital mode (Trunking only)
Turns the Site Lock function ON or OFF� When
this function is turned ON, the transceiver cancels
resuming a Roaming Scan, and stays on the current
site, regardless of the error rate� (p� 7-20)
Ext CH Sel Mode
Turns the External Channel Select function ON or
OFF�
When this function is ON, Memory channels are
selectable by only external input�
NOTE:
This function is activated when the external
unit is connected to the transceiver� To use the
function, set “MCH Select:1” ~ “MCH Select: 5” to any
pins, in the Port Setting screen of the programming
software�
Hook Scan
(For the Mobile types)
Turns the On Hook Scan function ON or OFF�
When this function is ON, after putting the microphone
in its hanger (on-Hook), the transceiver automatically
starts scanning�
Horn
(For the Mobile types)
Turns the Horn function ON or OFF�
When this function is ON, the HORN terminal of the
D-Sub 25 pin or Option Connector 22 pin is activated
after receiving a call with the Dec EXO or RX EXO
setting is ON�
L
This function is useful when the user is away from the
transceiver�
L
An external horn is required�
Keyset
In the Digital mode
Selects Keyset 1 or Keyset 2 for the Encryption
function�
NOTE:
•
To use the function, the optional UT-134
aes/des
encryption
unit
is required�
•
The Keysets are settable in the optional CS-KLD2
key
loader
software
�
Lone Worker
Turns the Lone Worker function ON or OFF�
When this function is ON, the transceiver
automatically enters the Emergency mode if no
operation occurs during the preset period�
Public Address
(For the Mobile types)
Adjusts the Audio Output level of the connected Public
Address (PA)�
Trunking