72
13
SPECIFICATIONS AND OPTIONS
12
13
■
Specifications
D
D
GENERAL
• Frequency coverage
:
Europe
Rx
118.000–173.995 MHz*
1
,
230.000–549.995 MHz*
2
,
810.000–999.990 MHz
Tx
144–146 MHz, 430–440 MHz
Italy
Rx
118.000–173.995 MHz*
1
,
230.000–549.995 MHz*
2
,
810.000–999.990 MHz
Tx
144–146 MHz, 430–434 MHz,
435–438 MHz
Europe-1
Tx/Rx
144–146 MHz, 430–440 MHz
*
1
Guaranteed: 144–146 MHz range only.; *
2
Guaranteed: 430–440 MHz range
• Type of emission
: FM, AM
(Receive only)
• Number of memory channels
: 512 (incl. 10 scan edges and 2 calls)
• Frequency resolution
: 5, 10, 12.5, 15, 20, 25, 30, 50, 100,
200 kHz
• Operating temperature range
: –10°C to +60°C
• Frequency stability
: ±10 ppm
(–10°C to +60°C)
• Power supply requirement
: 13.8 V DC ±15%
• Current drain
(at 13.8 V DC: approx.)
:
Transmit
at 55 W
12 A
Receive
standby
0.8 A
max. audio
1.0 A
• Antenna connector
: SO-239
(50
Ω
)
• Dimensions
(proj. not included)
: 141(W)
×
40(H)
×
185.4(D) mm
• Weight
(approx.)
: 1.2 kg
D
D
TRANSMITTER
• Modulation system
: Variable reactance frequency modulation
• Output power
: VHF
55/15/5 W
(approx.)
UHF
50/15/5 W
(approx.)
• Max. frequency deviation
: ±5.0 kHz
(wide)
±2.5 kHz
(narrow: approx.)
• Spurious emissions
: Less than –60 dB
• Microphone connector
: 8-pin modular
(600
Ω
)
D
D
RECEIVER
• Receive system
: Double-conversion superheterodyne
• Intermediate frequencies
: 1st: 46.05 MHz, 2nd: 450 kHz
• Sensitivity
(FM: at 12 dB SINAD/AM: at 10 dB S/N)
:
118.000–173.995 MHz
0.18 µV/0.45 µV
230.000–299.995 MHz
0.32 µV/0.79 µV
300.000–499.995 MHz
0.22 µV/0.63 µV
500.000–549.995 MHz
0.32 µV/Not specified
810.000–999.990 MHz
0.45 µV/Not specified
• Squelch sensitivity
†
(threshold)
: Less than 0.13 µV
• Selectivity :
Wide
More than 12 kHz/6 dB
Less than 30 kHz/60 dB
Narrow
More than 6 kHz/6 dB
Less than 20 kHz/60 dB
• Spurious and image rejection
: More than 60 dB
• AF output power
(at 13.8 V DC)
: More than 2.0 W
at 10% distortion with an
8
Ω
load
• Ext. speaker connectors
: 3-conductor 3.5 (d) mm (
1
⁄
8
″
)/8
Ω
All stated specifications are subject to change without notice or obligation.