N
Scan resume condition
D
Scan pause timer
The scan pauses when receiving signals according to the
scan pause time. It can be set from 2 to 20 sec. or unlimited.
q
Enter “PAUSE” in SCAN set mode.
MENU
¶
SCAN
¶
PAUSE
(p. 121)
(Push
[MENU
]
), (Push
[
]
(2)/
[
]
(8), then push
[
]
(5).)
w
Push
[
]
(2) or
[
]
(8) to select the desired scan pausing
time from 2–20 sec. (2 sec. steps) or “HOLD.”
• “2SEC”–“20SEC” : Scan pauses for 2–20 sec. while receiving a
signal.
• “HOLD”
: Scan pauses on a received a signal until it
disappears.
e
Push
[
]
(5) to return to SCAN set mode.
r
[MENU
]
to return to frequency indication.
D
Scan resume timer
The scan restarts after the signal disappears according to the
resume time. It can be set from 0–5 sec. or unlimited.
q
Enter “RESUME” in SCAN set mode.
MENU
¶
SCAN
¶
RESUME
(p. 122)
(Push
[MENU
]
), (Push
[
]
(2)/
[
]
(8), then push
[
]
(5).)
w
Push
[
]
(2) or
[
]
(8) to select the desired scan resume
time from 0–5 sec. (1 sec. steps) and “HOLD.”
• “0SEC”
: Scan restarts immediately after the signal dis-
appears.
• “1SEC”–“5SEC” : Scan restarts 1–5 sec. after the signal disap-
pears.
• “HOLD”
: Scan remains paused on the received signal
according to the scan pause timer even if it dis-
appears. Rotate
[DIAL]
to resume manually.
e
Push
[
]
(5) to return to SCAN set mode.
r
[MENU
]
to return to frequency indication.
Scan resume timer must be set shorter than the scan
pause timer, otherwise this timer does not activate.
110
10
SCAN OPERATION
Содержание IC-80AD
Страница 182: ...174 MEMO ...
Страница 183: ...175 MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ...
Страница 184: ...176 MEMO ...
Страница 185: ...177 MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ...
Страница 186: ...178 MEMO ...
Страница 187: ...179 MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ...