4 - 26
SOFTWARE ADJUSTMENTS–Continued
EXTERNAL
AGC
HF
S-METER
50 MHz
S-METER
REFERENCE
FREQUENCY
ADJUSTMENT
ADJUSTMENT CONDITION
DISPLAY
OPERATION
• Connect an SSG to [ANT1] connec-
tor and set as;
Frequency
: 14.1515 MHz
Level
: 3.2 mV* (–37 dBm)
Modulation
: OFF
• Set the SSG as;
Frequency
: 14.1515 MHz
Level
: OFF
• Set the SSG as;
Level
: 50 µV* (–73 dBm)
• Set the SSG as:
Level
: 50 mV* (–13 dBm)
• Set an SSG as;
Frequency
: 51.1515 MHz
Level
: OFF
• Set an SSG as;
Level
: 50 µV* (–73 dBm)
• Set an SSG as;
Level
: 50 mV* (–13 dBm)
• Connect a frequency counter to the
J490 (MAIN unit).
• Push [F2 (REF)] to enter the REF
adjustment mode.
1
2
1
2
3
1
2
3
1
AGC(RX-DSP)A
AGC(RX-DSP)B
HF S0 LEVEL
HF S9 LEVEL
S9+60 LEVEL
50M S0 LEVEL
50M S9 LEVEL
S9+60 LEVEL
REF OSC
Push [F-7 (SET)] to set the external AGC level
and selects the next adjustment item.
Push [F-7 (SET)] to set the external AGC level
and selects the next adjustment item.
• Push [F-7 (SET)] to set the HF S0 meter indi-
cation and selects the next adjustment item.
NEVER
change the SSG output level until 2
short beeps are sound.
• Push [F-7 (SET)] to set the HF S9 meter indi-
cation and selects the next adjustment item.
NEVER
change the SSG output level until 2
short beeps are sound.
• Push [F-7 (SET)] to set the HF S9+60 meter
indication and selects the next adjustment
item.
NEVER
change the SSG output level until 2
short beeps are sound.
• Push [F-7 (SET)] to set the 50 MHz S0 meter
indication and selects the next adjustment
item.
NEVER
change the SSG output level until 2
short beeps are sound.
• Push [F-7 (SET)] to set the 50MHz S9 meter
indication and selects the next adjustment
item.
NEVER
change the SSG output level until 2
short beeps are sound.
• Push [F-7 (SET)] to set the 50 MHz S9+60
meter indication and selects the opening
screen.
NEVER
change the SSG output level until 2
short beeps are sound.
Rotate [MAIN DIAL] to set the reference fre-
quency to 10.0000000 MHz.
Push [F-7 (SET)] to set the frequency and
return to the opening screen.
NOTE:
Adjustment the reference
frequency at least 5 minutes has
been past from the IC-7800’s main
power (on the rear panel) is turned
ON.
*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
After adjustment exiting from the adjustment mode when the transceiver is power OFF.
Содержание IC-7800
Страница 1: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 65 VOLTAGE DIAGRAM 67 Dec 2009 ...
Страница 79: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 60 VOLTAGE DIAGRAM 64 Feb 2009 ...
Страница 157: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 57 VOLTAGE DIAGRAM 59 Aug 2008 ...
Страница 245: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 57 VOLTAGE DIAGRAM 59 Jul 2008 ...
Страница 333: ...THE TRANSCEIVER i7800 SERVICE MANUAL S 14015HZ C1 2 Mar 2006 ...
Страница 489: ...5 10 15 20 25 30 35 40 45 50 55 60 65 0 Horizontal 5 10 15 0 25 30 35 20 40 Vertical BOTTOM VIEW MEMORY BOARD 8 12 ...
Страница 555: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 14015HZ C1 2 C 2004 2006 Icom Inc ...