3
REMOTE CONTROL
Remote control (CI-V) information
D
Command table
Cmd� Sub cmd�
Data
Description
00
Send the frequency data
(transceive)
01
Send the mode data (transceive)
02*
1
Read the band edge frequencies
03*
1
Read the operating frequency
04*
1
Read the operating mode
05*
2
Set the operating frequency
06*
2
Set the operating mode
07
Select the VFO mode
00
Select VFO A
01
Select VFO B
A0
Equalize VFO A and VFO B
L
When the split frequency
operation is OFF in the Memory
mode or the Call channel mode,
“FA” (NG) is returned�
B0
Exchange VFO A and VFO B�
L
When the split frequency
operation is OFF in the Memory
mode or the Call channel mode,
“FA” (NG) is returned�
08*
2
Select the Memory mode
0000 ~ 0099 Select the Memory channnel
( Memory channel: 0000 ~ 0099
Call channel:
0000 (144C1),
0001 (144C2),
0002 (430C1),
0003 (430C2))
A0
0000 ~ 0100 Select the Memory group
( Memory channel group:
0000 ~ 0099
Call channel group: 0100)
09
Memory write
0A
Memory copy to VFO
0B
Memory clear
0C*
1
Read frequency offset
0D*
2
Send frequency offset
0E
00
Cancel the scan
01
Start a Programmed/memory scan
02
Start a Programmed scan
03
Start a
∂
F scan
12
Start a Fine programmed scan
13
Start a Fine
∂
F scan
22
Start a Memory scan
23
Start a Select memory scan
24
Start a Mode Select scan
Ax*
2
(x=1 ~ 7)
Select
∂
F scan span
( x=1 (±5kHz),
x=2 (±10kHz),
x=3 (±20kHz), x=4 (±50kHz),
x=5 (±100kHz), x=6 (±500kHz),
x=7 (±1MHz))
B0*
2
Clear the Select channel setting
Cmd� Sub cmd�
Data
Description
0E
B1*
2
Set as select channel
L
The previously set number by
CI-V is set after turning power
ON, or “1” is selected if no
selection is performed�
01 ~ 03
Set the channel as a Select channel
(01=SEL1, 02=SEL2, 03=SEL3)
B2*
2
00 ~ 03
Set the Select memory scan
channel
( 00=ALL, 01=SEL1, 02=SEL2,
03=SEL3)
D0*
2
Set Scan resume OFF
D3*
2
Set Scan resume ON (Close&Delay)
0F
00*
1
Read Split OFF setting
01*
1
Read Split ON setting
11*
1
Read DUP– operation
12*
1
Read DUP+ operation
00*
2
Set Split function OFF
01*
2
Set Split function ON
10*
2
Set the simplex operation
11*
2
Set DUP– operation
12*
2
Set DUP+ operation
10*
00 ~ 13
Send/read the tuning step
( 00=OFF (10Hz or 1Hz)
01=100Hz 02=500Hz
03=1kHz 04=5kHz
05=6�25kHz 06=8�33kHz
07=9kHz 08=10kHz
09=12�5kHz 10=20kHz
11=25kHz 12=50kHz
13=100kHz)
11*
00
Send/read attenuator OFF setting
20
Send/read 20 dB attenuator setting
L
You can set in the HF and
50 MHz bands�
13
00
Speech all data by voice synthesizer
(S meter level, frequency, and mode)
01
Speech the operating frequency and
S meter level by voice synthesizer
02
Speech the operating mode by voice
synthesizer
L
The mode is announced after the
ongoing speech�
14*
01
0000 ~ 0255 Send/read the AF level
(0000=Minimum ~ 0255=Maximum)
02
0000 ~ 0255 Send/read the RF gain level
(0000=Minimum ~ 0255=Maximum)
03
0000 ~ 0255 Send/read the squelch level
(0000=Minimum ~ 0255=Maximum)
06
0000 ~ 0255 Send/read the NR level
(0000=0% ~ 0255=100%)
07
0000 ~ 0255 Send/read [TWIN PBT] (PBT1) position
( 0000=max� Counter Clockwise ~
0128=center ~ 0255=max� Clockwise)
08
0000 ~ 0255 Send/read [TWIN PBT] (PBT2)
position
( 0000=max� Counter Clockwise ~
0128=center ~ 0255=max� Clockwise)