background image

3

REMOTE CONTROL

Remote control (CI-V) information

 

D

Command table

Cmd� Sub cmd�

Data

Description

00

See p� 16�

Send the frequency data 

(transceive)

01

See p� 16�

Send the mode data (transceive)

02*

1

See p� 16

Read the band edge frequencies

03*

1

See p� 16

Read the operating frequency

04*

1

See p� 16

Read the operating mode

05*

2

See p� 16

Set the operating frequency

06*

2

See p� 16

Set the operating mode

07

Select the VFO mode

00

Select VFO A

01

Select VFO B

A0

Equalize VFO A and VFO B

 

L

When the split frequency 

operation is OFF in the Memory 

mode or the Call channel mode, 

“FA” (NG) is returned�

B0

Exchange VFO A and VFO B�

 

L

When the split frequency 

operation is OFF in the Memory 

mode or the Call channel mode, 

“FA” (NG) is returned�

08*

2

Select the Memory mode

0000 ~ 0099 Select the Memory channnel

( Memory channel:  0000 ~ 0099 

Call channel: 

 0000 (144C1), 

0001 (144C2), 

0002 (430C1), 

0003 (430C2))

A0

0000 ~ 0100 Select the Memory group

( Memory channel group: 

 

0000 ~ 0099 

Call channel group:  0100)

09

Memory write

0A

Memory copy to VFO

0B

Memory clear

0C*

1

See p� 16

Read frequency offset

0D*

2

See p� 16

Send frequency offset

0E

00

Cancel the scan

01

Start a Programmed/memory scan

02

Start a Programmed scan

03

Start a 

F scan

12

Start a Fine programmed scan

13

Start a Fine 

F scan

22

Start a Memory scan

23

Start a Select memory scan

24

Start a Mode Select scan

Ax*

2

 

(x=1 ~ 7)

Select 

F scan span

( x=1 (±5kHz), 

x=2 (±10kHz), 

x=3 (±20kHz),  x=4 (±50kHz), 

x=5 (±100kHz),  x=6 (±500kHz), 

x=7 (±1MHz))

B0*

2

Clear the Select channel setting

Cmd� Sub cmd�

Data

Description

0E

B1*

2

Set as select channel

 

L

The previously set number by 

CI-V is set after turning power 

ON, or “1” is selected if no 

selection is performed�

01 ~ 03

Set the channel as a Select channel

(01=SEL1, 02=SEL2, 03=SEL3)

B2*

2

00 ~ 03

Set the Select memory scan 

channel

( 00=ALL, 01=SEL1, 02=SEL2, 

03=SEL3)

D0*

2

Set Scan resume OFF

D3*

2

Set Scan resume ON (Close&Delay)

0F

00*

1

Read Split OFF setting

01*

1

Read Split ON setting

11*

1

Read DUP– operation

12*

1

Read DUP+ operation

00*

2

Set Split function OFF

01*

2

Set Split function ON

10*

2

Set the simplex operation

11*

2

Set DUP– operation

12*

2

Set DUP+ operation

10*

00 ~ 13

Send/read the tuning step

( 00=OFF (10Hz or 1Hz) 

01=100Hz 02=500Hz 

03=1kHz 04=5kHz 

05=6�25kHz 06=8�33kHz 

07=9kHz 08=10kHz 

09=12�5kHz 10=20kHz 

11=25kHz 12=50kHz 

13=100kHz)

11*

00

Send/read attenuator OFF setting

20

Send/read 20 dB attenuator setting

 

L

You can set in the HF and 

50 MHz bands�

13

00

Speech all data by voice synthesizer

(S meter level, frequency, and mode)

01

Speech the operating frequency and 

S meter level by voice synthesizer

02

Speech the operating mode by voice 

synthesizer

 

L

The mode is announced after the 

ongoing speech�

14*

01

0000 ~ 0255 Send/read the AF level

(0000=Minimum ~ 0255=Maximum)

02

0000 ~ 0255 Send/read the RF gain level

(0000=Minimum ~ 0255=Maximum)

03

0000 ~ 0255 Send/read the squelch level

(0000=Minimum ~ 0255=Maximum)

06

0000 ~ 0255 Send/read the NR level

(0000=0% ~ 0255=100%)

07

0000 ~ 0255 Send/read [TWIN PBT] (PBT1) position

( 0000=max� Counter Clockwise ~  

0128=center ~ 0255=max� Clockwise)

08

0000 ~ 0255 Send/read [TWIN PBT] (PBT2) 

position

( 0000=max� Counter Clockwise ~  

0128=center ~ 0255=max� Clockwise)

Содержание IC-705

Страница 1: ...CI V REFERENCE GUIDE HF VHF UHF ALL MODE TRANSCEIVER 705...

Страница 2: ...Remote MIC Key setting 20 Color settings 20 Bandscope edge frequency settings 20 Manually entered position data 21 D PRS Symbol setting 21 Alarm area Group setting 21 Data mode with filter width setti...

Страница 3: ...to controller IC 705 to controller D DCI V connection The transceiver s operating frequency mode VFO and memory selection can be remotely controlled using a PC The Icom Communications Interface V CI...

Страница 4: ...ct channel setting Cmd Sub cmd Data Description 0E B1 2 Set as select channel L LThe previously set number by CI V is set after turning power ON or 1 is selected if no selection is performed 01 03 Set...

Страница 5: ...AMP2 In the 144 or 430 MHz bands 00 OFF 01 ON 12 01 03 Send read the AGC time constant 01 FAST 02 MID 03 SLOW Remote control CI V information D D Command table Cmd Sub cmd Data Description 16 22 00 01...

Страница 6: ...level 00 5 10 5 0018 00 10 TX SSB Send read TX Tone Treble level 00 5 10 5 0019 See p 19 TX SSB Send read TX bandwidth for wide Cmd Sub cmd Data Description 1A 05 SET Tone Control TBW 0020 See p 19 TX...

Страница 7: ...H setting 00 OFF 01 ON Kerchunk 02 ON All Cmd Sub cmd Data Description 1A 05 SET Function 0057 00 01 SPEECH Send read the RX CS SPEECH setting 00 OFF 01 ON 0058 00 01 SPEECH Send read the MIC Up Down...

Страница 8: ...Digital Monitor setting 00 Auto 01 Digital 02 Analog Cmd Sub cmd Data Description 1A 05 SET DV Set 0097 00 01 Send read the Digital Repeater Set setting 00 OFF 01 ON 0098 00 01 Send read the DV Auto...

Страница 9: ...ed in the USB SEND or USB Keying CW item 0128 00 01 External Keypad Send read the VOICE setting 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 SET Connectors 0129 00 01 External Keypad Send read the...

Страница 10: ...00 01 Send read the System Language setting 00 English 01 Japanese Cmd Sub cmd Data Description 1A 05 SET Time Set 0165 20000101 20991231 Date Time Send read the Date setting 20000101 2000 1 1 2099123...

Страница 11: ...See p 20 FIX Edges 20 00 22 00 Send read the No 2 setting Cmd Sub cmd Data Description 1A 05 SCOPE SCOPE SET 0211 See p 20 FIX Edges 20 00 22 00 Send read the No 3 setting 0212 See p 20 FIX Edges 22 0...

Страница 12: ...nd read the FFT Scope Waveform Color setting 0259 00 01 Send read the Decode USOS setting 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 DECODE RTTY DECODE SET 0260 00 01 Send read the Decode New Lin...

Страница 13: ...ing Up to 43 characters Cmd Sub cmd Data Description 1A 05 GPS GPS TX Mode D PRS TX Format Position 0301 00 02 Send read the Time Stamp setting 00 OFF 01 DHM 02 HMS 0302 00 01 Send read the Altitude s...

Страница 14: ...01 DHM 02 HMS GPS GPS TX Mode NMEA 0339 6 00 01 GPS Sentence Send read the RMC setting 00 OFF 01 ON 0340 6 00 01 GPS Sentence Send read the GGA setting 00 OFF 01 ON 0341 6 00 01 GPS Sentence Send rea...

Страница 15: ...d edge frequencies 02 1 Read number of user set TX frequency band 03 See p 16 Send read the user set TX band edge frequencies Cmd Sub cmd Data Description 1F 00 See p 22 SET My Station Send read the M...

Страница 16: ...n or Sub scope setting 00 Main fixed 13 00 Send read the Single Dual scope setting 00 Single fixed 14 0000 0001 Send read the Scope Center mode or Fixed mode setting 0000 CENTER mode 0001 FIX mode 15...

Страница 17: ...d to transmit a string of characters with no inter character space Band edge frequency settings Command 02 1E 01 1E 03 q X X X w e r t y u i o 0 1 2 X X X X X X X 0 X 2 D X X X X X X X X 0 X 10 Hz dig...

Страница 18: ...squelch setting X 0 15 0 Digital squelch function OFF 1 Digital call sign squelch function ON DSQL 2 Digital code squelch function ON CSQL Fixed 16 18 Repeater tone frequency setting 19 21 Repeater to...

Страница 19: ...ency and operating mode should be added after the frequency band code and the register code as shown below See 6 52 on Memory content p 17 1 Frequency band codes Code Freq band Frequency range unit MH...

Страница 20: ...CW 10 40 600 Hz 3 6 kHz 100 Hz RTTY 10 31 600 2 7 kHz 100 Hz AM 0 49 200 Hz 10 0 kHz 200 Hz AGC time constant settings Command 1A 04 Data AGC time constant sec SSB CW RTTY AM 00 OFF OFF 01 0 1 0 3 02...

Страница 21: ...H 18 MODE 19 RF Power 20 Voice TX T1 21 Voice TX T2 22 Keyer Memory M1 23 Keyer Memory M2 24 T CALL 25 RX CS 26 TS 27 MPAD 28 SPLIT 29 A B Only for European version Color settings Command 1A 05 0180 0...

Страница 22: ...5 Altitude 0 1 meter steps When reading the contents with no altitude sends 12 13 14 and 15 as FF When sending the contents with no altitude set 12 13 14 and 15 to FF D PRS Symbol setting Command 1A 0...

Страница 23: ...p to 20 characters See Codes for character entries p 18 FF stops sending or reading messages DV RX call sign data Command 20 0001 0002 X X X X X X X X X X X X X X X X X X X X X X X X 1 2 3 10 11 14 15...

Страница 24: ...you select 1 bit4 0 1 Receiving a signal When the audio tone can be heard select 1 bit3 0 1 Receiving a BK call While receiving a BK call select 1 bit2 0 1 Receiving a EMR call While receiving a EMR...

Страница 25: ...0 8 360 N 9 81 1561 5120 9 43 51 Name 9 ASCII characters 00h EFh 52 Type 1 Live 0 Killed L LThe item that is not contained the received data is filled with FF L LFF No signal has been received since t...

Страница 26: ...9 40 41 42 X X X X 36 38 X X X X 43 44 X X X X 45 46 X X X X 47 49 Data number GPS D PRS message Command 20 0401 0402 1 9 10 52 Variable length X X X X X X X X 1 9 Call sign SSID 9 ASCII characters A...

Страница 27: ...AM 07 CW R 03 FIL3 03 CW 08 RTTY R 04 RTTY 17 DV Scope waveform data Command 27 00 Outputs the waveform data to the controller X X X X 0 0 X X X X X X X X X X 1 2 3 4 5 6 7 1 00 Fixed 2 Order of divis...

Страница 28: ...requency settings Command 27 1E 1 0 X X X X 2 3 4 5 6 7 8 9 10 11 12 X X X X X X X 0 X X X X X X X X X 0 X 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 100 Hz digit 0 9 100 kHz digit 0 9 10 kHz digi...

Страница 29: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7560 8EX 1 2020 Icom Inc Jul 2020...