background image

14

REMOTE CONTROL

Cmd� Sub cmd�

Data

Description

1A*

05

VOX

0359 00 ~ 20

Send/read the VOX DELAY setting

( 00=0�0s ~ 20=2�0s in 0�1s steps)

0360 00 ~ 03

Send/read the VOICE DELAY setting

( 00=OFF,  01=SHORT,   

02=MID, 03=LONG)

CD

0361 00/01

Send/read the Call Sign Display/

Name Display setting

( 00=Call Sign Display,  

01=Name Display)

GPS Position

0362 00 ~ 02

Send/read the Compass Direction 

setting

( 00=Heading Up, 01=North Up,  

02=South Up)

06

See p� 21�

Send/read the DATA mode setting

07

00/01

Send/read the NTP server access

(00=Terminate, 01=Initiate)

08*

1

00 ~ 02

Read NTP server access result

(00= Accessing, or have not 

accessed after Power ON,

 01=Succeeded, 02=Failed)

09*

1

00/01

Read the OVF indicator status

(00=OFF, 01=ON)

0A

00 ~ 02

Send/read the Share Pictures 

function status

( 00=OFF, 01=ON, 02=ON (Repeat))

 

L

While transmitting the picture 

using the DV Fast Data function, 

sends ON even if the status is set 

to OFF�

0B*

1

00/01

Read the type of power supply 

based on the current voltage

( 00=External power supply,  

01=Battery pack)

1B*

00

See p� 21�

Send/read the Repeater tone frequency

01

See p� 21�

Send/read the TSQL tone frequency

02

See p� 21�

Send/read the DTCS code and polarity

07

See p� 22�

Send/read the CSQL code (DV mode)

1C

00*

00/01

Send/read the transceiver’s status

(00=RX, 01=TX)

01*

00 ~ 02

Send/read the Antenna tuner's status

(00=OFF, 01=ON, 02=Tune)

02*

00/01

Send/read the Transmit frequency 

monitor (XFC)

(00=OFF, 01=ON)

03*

1

See p� 16�

Read the transmit frequency

1E

00*

1

Read number of available TX 

frequency band

01*

1

See p� 16�

Read TX band edge frequencies

02*

1

Read number of user-set TX 

frequency band

03*

See p� 16�

Send/read the user-set TX band 

edge frequencies

Cmd� Sub cmd�

Data

Description

1F*

00

See p� 22

SET > My Station > 

Send/read the My Call Sign setting

01

See p� 22

CS > 

Send/read the UR, R1, R2 setting

02

See p� 22

SET > My Station > 

Send/read the TX Message setting

20

00 00*

00/01*

7

Send/read the Auto DV RX Call 

signs output

(00=OFF, 01=ON)

01

See p� 22

Output DV RX Call signs for 

transceive

02*

1

See p� 22

Read Auto DV RX Call signs

01 00*

00/01*

7

Send/read the Auto DV RX message 

output

(00=OFF, 01=ON)

01

See p� 23

Output DV RX message for 

transceive

02*

1

See p� 23

Read Auto DV RX message

20

02 00*

00/01*

7

Send/read the Auto DV RX status 

output

(00=OFF, 01=ON)

01

See p� 23

Output DV RX status for transceive

02*

1

See p� 23

Read Auto DV RX status

03 00*

00/01

Send/read the Auto DV RX 

GPS/D-PRS data output

(00=OFF, 01=ON)

0100 See p� 23

Output DV RX GPS/D-PRS Position 

for transceive

0101 See p� 24

Output DV RX D-PRS Object status 

for transceive

0102 See p� 24

Output DV RX D-PRS Item status 

for transceive

0103 See p� 25

Output DV RX D-PRS Weather 

status for transceive

0200*

1

See p� 23

Read Auto DV RX GPS/D-PRS 

Position status

0201*

1

See p� 24

Read Auto DV RX D-PRS Object 

status

0202*

1

See p� 24

Read Auto DV RX D-PRS Item 

status

0203*

1

See p� 25

Read Auto DV RX D-PRS Weather 

status

04 00*

00/01

Send/read Auto DV RX GPS/D-PRS 

message output

(00=OFF, 01=ON)

01

See p� 25

Output DV RX D-PRS message for 

transceive

02*

1

See p� 25

Read Auto DV RX D-PRS message 

status

21*

00

See p� 25

Send/read the RIT frequency

01

00/01

Send/read the RIT setting

(00=OFF, 01=ON)

02

00/01

Send/read the ∂

TX setting

(00=OFF, 01=ON)

Remote control (CI-V) information

 

D

Command table

Содержание IC-705

Страница 1: ...CI V REFERENCE GUIDE HF VHF UHF ALL MODE TRANSCEIVER 705...

Страница 2: ...Remote MIC Key setting 20 Color settings 20 Bandscope edge frequency settings 20 Manually entered position data 21 D PRS Symbol setting 21 Alarm area Group setting 21 Data mode with filter width setti...

Страница 3: ...to controller IC 705 to controller D DCI V connection The transceiver s operating frequency mode VFO and memory selection can be remotely controlled using a PC The Icom Communications Interface V CI...

Страница 4: ...ct channel setting Cmd Sub cmd Data Description 0E B1 2 Set as select channel L LThe previously set number by CI V is set after turning power ON or 1 is selected if no selection is performed 01 03 Set...

Страница 5: ...AMP2 In the 144 or 430 MHz bands 00 OFF 01 ON 12 01 03 Send read the AGC time constant 01 FAST 02 MID 03 SLOW Remote control CI V information D D Command table Cmd Sub cmd Data Description 16 22 00 01...

Страница 6: ...level 00 5 10 5 0018 00 10 TX SSB Send read TX Tone Treble level 00 5 10 5 0019 See p 19 TX SSB Send read TX bandwidth for wide Cmd Sub cmd Data Description 1A 05 SET Tone Control TBW 0020 See p 19 TX...

Страница 7: ...H setting 00 OFF 01 ON Kerchunk 02 ON All Cmd Sub cmd Data Description 1A 05 SET Function 0057 00 01 SPEECH Send read the RX CS SPEECH setting 00 OFF 01 ON 0058 00 01 SPEECH Send read the MIC Up Down...

Страница 8: ...Digital Monitor setting 00 Auto 01 Digital 02 Analog Cmd Sub cmd Data Description 1A 05 SET DV Set 0097 00 01 Send read the Digital Repeater Set setting 00 OFF 01 ON 0098 00 01 Send read the DV Auto...

Страница 9: ...ed in the USB SEND or USB Keying CW item 0128 00 01 External Keypad Send read the VOICE setting 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 SET Connectors 0129 00 01 External Keypad Send read the...

Страница 10: ...00 01 Send read the System Language setting 00 English 01 Japanese Cmd Sub cmd Data Description 1A 05 SET Time Set 0165 20000101 20991231 Date Time Send read the Date setting 20000101 2000 1 1 2099123...

Страница 11: ...See p 20 FIX Edges 20 00 22 00 Send read the No 2 setting Cmd Sub cmd Data Description 1A 05 SCOPE SCOPE SET 0211 See p 20 FIX Edges 20 00 22 00 Send read the No 3 setting 0212 See p 20 FIX Edges 22 0...

Страница 12: ...nd read the FFT Scope Waveform Color setting 0259 00 01 Send read the Decode USOS setting 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 DECODE RTTY DECODE SET 0260 00 01 Send read the Decode New Lin...

Страница 13: ...ing Up to 43 characters Cmd Sub cmd Data Description 1A 05 GPS GPS TX Mode D PRS TX Format Position 0301 00 02 Send read the Time Stamp setting 00 OFF 01 DHM 02 HMS 0302 00 01 Send read the Altitude s...

Страница 14: ...01 DHM 02 HMS GPS GPS TX Mode NMEA 0339 6 00 01 GPS Sentence Send read the RMC setting 00 OFF 01 ON 0340 6 00 01 GPS Sentence Send read the GGA setting 00 OFF 01 ON 0341 6 00 01 GPS Sentence Send rea...

Страница 15: ...d edge frequencies 02 1 Read number of user set TX frequency band 03 See p 16 Send read the user set TX band edge frequencies Cmd Sub cmd Data Description 1F 00 See p 22 SET My Station Send read the M...

Страница 16: ...n or Sub scope setting 00 Main fixed 13 00 Send read the Single Dual scope setting 00 Single fixed 14 0000 0001 Send read the Scope Center mode or Fixed mode setting 0000 CENTER mode 0001 FIX mode 15...

Страница 17: ...d to transmit a string of characters with no inter character space Band edge frequency settings Command 02 1E 01 1E 03 q X X X w e r t y u i o 0 1 2 X X X X X X X 0 X 2 D X X X X X X X X 0 X 10 Hz dig...

Страница 18: ...squelch setting X 0 15 0 Digital squelch function OFF 1 Digital call sign squelch function ON DSQL 2 Digital code squelch function ON CSQL Fixed 16 18 Repeater tone frequency setting 19 21 Repeater to...

Страница 19: ...ency and operating mode should be added after the frequency band code and the register code as shown below See 6 52 on Memory content p 17 1 Frequency band codes Code Freq band Frequency range unit MH...

Страница 20: ...CW 10 40 600 Hz 3 6 kHz 100 Hz RTTY 10 31 600 2 7 kHz 100 Hz AM 0 49 200 Hz 10 0 kHz 200 Hz AGC time constant settings Command 1A 04 Data AGC time constant sec SSB CW RTTY AM 00 OFF OFF 01 0 1 0 3 02...

Страница 21: ...H 18 MODE 19 RF Power 20 Voice TX T1 21 Voice TX T2 22 Keyer Memory M1 23 Keyer Memory M2 24 T CALL 25 RX CS 26 TS 27 MPAD 28 SPLIT 29 A B Only for European version Color settings Command 1A 05 0180 0...

Страница 22: ...5 Altitude 0 1 meter steps When reading the contents with no altitude sends 12 13 14 and 15 as FF When sending the contents with no altitude set 12 13 14 and 15 to FF D PRS Symbol setting Command 1A 0...

Страница 23: ...p to 20 characters See Codes for character entries p 18 FF stops sending or reading messages DV RX call sign data Command 20 0001 0002 X X X X X X X X X X X X X X X X X X X X X X X X 1 2 3 10 11 14 15...

Страница 24: ...you select 1 bit4 0 1 Receiving a signal When the audio tone can be heard select 1 bit3 0 1 Receiving a BK call While receiving a BK call select 1 bit2 0 1 Receiving a EMR call While receiving a EMR...

Страница 25: ...0 8 360 N 9 81 1561 5120 9 43 51 Name 9 ASCII characters 00h EFh 52 Type 1 Live 0 Killed L LThe item that is not contained the received data is filled with FF L LFF No signal has been received since t...

Страница 26: ...9 40 41 42 X X X X 36 38 X X X X 43 44 X X X X 45 46 X X X X 47 49 Data number GPS D PRS message Command 20 0401 0402 1 9 10 52 Variable length X X X X X X X X 1 9 Call sign SSID 9 ASCII characters A...

Страница 27: ...AM 07 CW R 03 FIL3 03 CW 08 RTTY R 04 RTTY 17 DV Scope waveform data Command 27 00 Outputs the waveform data to the controller X X X X 0 0 X X X X X X X X X X 1 2 3 4 5 6 7 1 00 Fixed 2 Order of divis...

Страница 28: ...requency settings Command 27 1E 1 0 X X X X 2 3 4 5 6 7 8 9 10 11 12 X X X X X X X 0 X X X X X X X X X 0 X 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 100 Hz digit 0 9 100 kHz digit 0 9 10 kHz digi...

Страница 29: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7560 8EX 1 2020 Icom Inc Jul 2020...

Отзывы: