26
REMOTE CONTROL
Remote control (CI-V) information
D
Command formats
•
Selected or unselected VFO frequency settings
Command: 25
X X X X X X X X X X X X
Operating frequency
00=Selected VFO
01=Unselected VFO
See “Operating frequency�” (p� 16)
L
When using the DR function, the transceiver returns
“FA” (NG) because these cannot be set to 01�
• When VFO A is selected
00=frequency of VFO A changes
01=frequency of VFO B changes
• When VFO B is selected
00=frequency of VFO B changes
01=frequency of VFO A changes
•
Selected or unselected VFO’s operating
mode and filter settings
Command: 26
Both data and filter settings can be skipped�
In that case, “DATA OFF” and the default filter
setting of the operating mode is automatically
selected�
1
Operating mode setting
2
Data mode setting
3
Filter setting
00=Selected VFO
01=Unselected VFO
X
X
X
X
X
X
X
X
L
When using the DR function, the transceiver returns
“FA” (NG) because these cannot be set to 01�
• When VFO A is selected
00 = operating mode of VFO A changes
01 = operating mode of VFO B changes
• When VFO B is selected
00 = operating mode of VFO B changes
01 = operating mode of VFO A changes
1
Operating mode
setting
2
Data mode
setting
3
Filter
setting
00:LSB
05:FM
00: Data mode OFF 01:FIL1
01:USB
06:WFM
01: Data mode ON 02:FIL2
02:AM
07:CW-R
—
03:FIL3
03:CW
08:RTTY-R
—
—
04:RTTY
17:DV
—
—
•
Scope waveform data
Command: 27 00
Outputs the waveform data to the controller�
X X
X X
0 0
X X
X X
X X
X X ������ X X
1
2
3
4
5
6
7
1
: 00 (Fixed)
2
Order of division data (Current): 01~11
3
Division number (Maximum): 01(WLAN), 11(USB)
L
When data is sent to the controller using
the WLAN function, all data is sent together�
However, when the data is sent through the
[microUSB] port, the data is divided by 11 and
sent in sequential order�
L
The 1st data sends only the wave information
(
1
~
6
) without the waveform data (
7
)� The
2nd or later data sends the minimum wave
information (
1
~
3
) with waveform data (
7
)�
4
Center or Fixed mode data:
• 00 = Center mode scope
• 01 = Fixed mode scope
5
Waveform information:
The waveform information is different between
the Center mode and the Fixed mode�
• In the Center mode:
Center frequency and span are sent�
See page 16 for Operating frequency data,
and the Scope span settings to the right�
• In the Fixed mode:
Lower edge and higher edge frequencies are
sent See page 27 for Scope Fixed edge
frequency settings
3
~
12
�
6
Out of range information:
• 00 = In range
• 01 = Out of range
L
If the scope data is out of range, the waveform
data (
7
) is omitted�
7
Waveform data:
The transceiver outputs the drawn waveform
data� The data range or data length of the
waveform data is judged by the controller�
(The data range is basically the same as the
display size of the scope on the controller�)
• Data range: 0 ~ 160
• Data length: 475