background image

26

REMOTE CONTROL

Remote control (CI-V) information

 

D

Command formats

 

Selected or unselected VFO frequency settings

Command: 25

X X X X X X X X X X X X

Operating frequency

00=Selected VFO
01=Unselected VFO

See “Operating frequency�” (p� 16)

 

L

When using the DR function, the transceiver returns 

“FA” (NG) because these cannot be set to 01�

 • When VFO A is selected 

00=frequency of VFO A changes 

01=frequency of VFO B changes

 • When VFO B is selected 

00=frequency of VFO B changes 

01=frequency of VFO A changes

 

Selected or unselected VFO’s operating 

mode and filter settings

Command: 26

Both data and filter settings can be skipped� 

In that case, “DATA OFF” and the default filter 

setting of the operating mode is automatically 

selected�

1

Operating mode setting

2

Data mode setting

3

Filter setting

00=Selected VFO
01=Unselected VFO

X

X

X

X

X

X

X

X

 

L

When using the DR function, the transceiver returns 

“FA” (NG) because these cannot be set to 01�

 • When VFO A is selected 

00 = operating mode of VFO A changes 

01 = operating mode of VFO B changes

 • When VFO B is selected 

00 = operating mode of VFO B changes 

01 = operating mode of VFO A changes

1

  Operating mode 

setting

2

  Data mode 

setting

3

   Filter 

setting

00:LSB

05:FM

00: Data mode OFF 01:FIL1

01:USB

06:WFM

01: Data mode ON 02:FIL2

02:AM

07:CW-R

03:FIL3

03:CW

08:RTTY-R

04:RTTY

17:DV

 

Scope waveform data

Command:  27 00

Outputs the waveform data to the controller�

X X

X X

0 0

X X

X X

X X

X X ������ X X

1

2

3

4

5

6

7

1

: 00 (Fixed)

2

 Order of division data (Current): 01~11

3

  Division number (Maximum): 01(WLAN), 11(USB)

 

L

When data is sent to the controller using 

the WLAN function, all data is sent together� 

However, when the data is sent through the 

[microUSB] port, the data is divided by 11 and 

sent in sequential order�

 

L

The 1st data sends only the wave information 

(

1

 ~ 

6

) without the waveform data (

7

)� The 

2nd or later data sends the minimum wave 

information (

1

 ~ 

3

) with waveform data (

7

)�

4

 Center or Fixed mode data:

 • 00 = Center mode scope

 • 01 = Fixed mode scope

5

  Waveform information: 

The waveform information is different between 

the Center mode and the Fixed mode�

 • In the Center mode: 

Center frequency and span are sent� 

See page 16 for Operating frequency data, 

and the Scope span settings to the right�

 • In the Fixed mode: 

Lower edge and higher edge frequencies are 

sent See page 27 for Scope Fixed edge 

frequency settings 

3

 ~ 

12

6

  Out of range information:

 • 00 = In range

 • 01 = Out of range

 

L

If the scope data is out of range, the waveform 

data (

7

) is omitted�

7

  Waveform data: 

The transceiver outputs the drawn waveform 

data� The data range or data length of the 

waveform data is judged by the controller� 

(The data range is basically the same as the 

display size of the scope on the controller�)

 • Data range: 0 ~ 160

 • Data length: 475

Содержание IC-705

Страница 1: ...CI V REFERENCE GUIDE HF VHF UHF ALL MODE TRANSCEIVER 705...

Страница 2: ...Remote MIC Key setting 20 Color settings 20 Bandscope edge frequency settings 20 Manually entered position data 21 D PRS Symbol setting 21 Alarm area Group setting 21 Data mode with filter width setti...

Страница 3: ...to controller IC 705 to controller D DCI V connection The transceiver s operating frequency mode VFO and memory selection can be remotely controlled using a PC The Icom Communications Interface V CI...

Страница 4: ...ct channel setting Cmd Sub cmd Data Description 0E B1 2 Set as select channel L LThe previously set number by CI V is set after turning power ON or 1 is selected if no selection is performed 01 03 Set...

Страница 5: ...AMP2 In the 144 or 430 MHz bands 00 OFF 01 ON 12 01 03 Send read the AGC time constant 01 FAST 02 MID 03 SLOW Remote control CI V information D D Command table Cmd Sub cmd Data Description 16 22 00 01...

Страница 6: ...level 00 5 10 5 0018 00 10 TX SSB Send read TX Tone Treble level 00 5 10 5 0019 See p 19 TX SSB Send read TX bandwidth for wide Cmd Sub cmd Data Description 1A 05 SET Tone Control TBW 0020 See p 19 TX...

Страница 7: ...H setting 00 OFF 01 ON Kerchunk 02 ON All Cmd Sub cmd Data Description 1A 05 SET Function 0057 00 01 SPEECH Send read the RX CS SPEECH setting 00 OFF 01 ON 0058 00 01 SPEECH Send read the MIC Up Down...

Страница 8: ...Digital Monitor setting 00 Auto 01 Digital 02 Analog Cmd Sub cmd Data Description 1A 05 SET DV Set 0097 00 01 Send read the Digital Repeater Set setting 00 OFF 01 ON 0098 00 01 Send read the DV Auto...

Страница 9: ...ed in the USB SEND or USB Keying CW item 0128 00 01 External Keypad Send read the VOICE setting 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 SET Connectors 0129 00 01 External Keypad Send read the...

Страница 10: ...00 01 Send read the System Language setting 00 English 01 Japanese Cmd Sub cmd Data Description 1A 05 SET Time Set 0165 20000101 20991231 Date Time Send read the Date setting 20000101 2000 1 1 2099123...

Страница 11: ...See p 20 FIX Edges 20 00 22 00 Send read the No 2 setting Cmd Sub cmd Data Description 1A 05 SCOPE SCOPE SET 0211 See p 20 FIX Edges 20 00 22 00 Send read the No 3 setting 0212 See p 20 FIX Edges 22 0...

Страница 12: ...nd read the FFT Scope Waveform Color setting 0259 00 01 Send read the Decode USOS setting 00 OFF 01 ON Cmd Sub cmd Data Description 1A 05 DECODE RTTY DECODE SET 0260 00 01 Send read the Decode New Lin...

Страница 13: ...ing Up to 43 characters Cmd Sub cmd Data Description 1A 05 GPS GPS TX Mode D PRS TX Format Position 0301 00 02 Send read the Time Stamp setting 00 OFF 01 DHM 02 HMS 0302 00 01 Send read the Altitude s...

Страница 14: ...01 DHM 02 HMS GPS GPS TX Mode NMEA 0339 6 00 01 GPS Sentence Send read the RMC setting 00 OFF 01 ON 0340 6 00 01 GPS Sentence Send read the GGA setting 00 OFF 01 ON 0341 6 00 01 GPS Sentence Send rea...

Страница 15: ...d edge frequencies 02 1 Read number of user set TX frequency band 03 See p 16 Send read the user set TX band edge frequencies Cmd Sub cmd Data Description 1F 00 See p 22 SET My Station Send read the M...

Страница 16: ...n or Sub scope setting 00 Main fixed 13 00 Send read the Single Dual scope setting 00 Single fixed 14 0000 0001 Send read the Scope Center mode or Fixed mode setting 0000 CENTER mode 0001 FIX mode 15...

Страница 17: ...d to transmit a string of characters with no inter character space Band edge frequency settings Command 02 1E 01 1E 03 q X X X w e r t y u i o 0 1 2 X X X X X X X 0 X 2 D X X X X X X X X 0 X 10 Hz dig...

Страница 18: ...squelch setting X 0 15 0 Digital squelch function OFF 1 Digital call sign squelch function ON DSQL 2 Digital code squelch function ON CSQL Fixed 16 18 Repeater tone frequency setting 19 21 Repeater to...

Страница 19: ...ency and operating mode should be added after the frequency band code and the register code as shown below See 6 52 on Memory content p 17 1 Frequency band codes Code Freq band Frequency range unit MH...

Страница 20: ...CW 10 40 600 Hz 3 6 kHz 100 Hz RTTY 10 31 600 2 7 kHz 100 Hz AM 0 49 200 Hz 10 0 kHz 200 Hz AGC time constant settings Command 1A 04 Data AGC time constant sec SSB CW RTTY AM 00 OFF OFF 01 0 1 0 3 02...

Страница 21: ...H 18 MODE 19 RF Power 20 Voice TX T1 21 Voice TX T2 22 Keyer Memory M1 23 Keyer Memory M2 24 T CALL 25 RX CS 26 TS 27 MPAD 28 SPLIT 29 A B Only for European version Color settings Command 1A 05 0180 0...

Страница 22: ...5 Altitude 0 1 meter steps When reading the contents with no altitude sends 12 13 14 and 15 as FF When sending the contents with no altitude set 12 13 14 and 15 to FF D PRS Symbol setting Command 1A 0...

Страница 23: ...p to 20 characters See Codes for character entries p 18 FF stops sending or reading messages DV RX call sign data Command 20 0001 0002 X X X X X X X X X X X X X X X X X X X X X X X X 1 2 3 10 11 14 15...

Страница 24: ...you select 1 bit4 0 1 Receiving a signal When the audio tone can be heard select 1 bit3 0 1 Receiving a BK call While receiving a BK call select 1 bit2 0 1 Receiving a EMR call While receiving a EMR...

Страница 25: ...0 8 360 N 9 81 1561 5120 9 43 51 Name 9 ASCII characters 00h EFh 52 Type 1 Live 0 Killed L LThe item that is not contained the received data is filled with FF L LFF No signal has been received since t...

Страница 26: ...9 40 41 42 X X X X 36 38 X X X X 43 44 X X X X 45 46 X X X X 47 49 Data number GPS D PRS message Command 20 0401 0402 1 9 10 52 Variable length X X X X X X X X 1 9 Call sign SSID 9 ASCII characters A...

Страница 27: ...AM 07 CW R 03 FIL3 03 CW 08 RTTY R 04 RTTY 17 DV Scope waveform data Command 27 00 Outputs the waveform data to the controller X X X X 0 0 X X X X X X X X X X 1 2 3 4 5 6 7 1 00 Fixed 2 Order of divis...

Страница 28: ...requency settings Command 27 1E 1 0 X X X X 2 3 4 5 6 7 8 9 10 11 12 X X X X X X X 0 X X X X X X X X X 0 X 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 100 Hz digit 0 9 100 kHz digit 0 9 10 kHz digi...

Страница 29: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7560 8EX 1 2020 Icom Inc Jul 2020...

Отзывы: