19
REMOTE CONTROL
Remote control (CI-V) information
D
Command formats
•
Keyer memory character entries
Command: 1A 02
- Character codes
Character ASCII code
Description
0 ~ 9
30 ~ 39
Numbers
A ~ Z
41 ~ 5A
Letters
Space
20
Word space
/
2F
Symbol
?
3F
Symbol
,
2C
Symbol
�
2E
Symbol
@
40
Symbol
^
5E
Example: to send
BT
,
enter ^4254
*
2A
Inserts the contest number
(can be used for 1 channel only)
L
Information
• “FA” (NG) is returned if you insert the content
number in more than 1 channel�
• Spaces after the end of the sentence are not
necessary�
• To clear the Keyer memory contents, send one or
more spaces�
•
Keyer memory content
Command: 1A 02
X
1
: Channel data
01=M1 05=M5
02=M2 06=M6
03=M3 07=M7
04=M4 08=M8
2
~
71
: Text data
X X X …… X X
•
IF filter width settings
Command: 1A 03
Mode
Data
Steps
SSB/CW/RTTY
0 ~ 9
50 ~ 500 Hz (50 Hz)
SSB/CW
10 ~ 40 600 Hz ~ 3�6 kHz (100 Hz)
RTTY
10 ~ 31 600 ~ 2�7 kHz (100 Hz)
AM
0 ~ 49
200 Hz ~ 10�0 kHz (200 Hz)
•
AGC time constant settings
Command: 1A 04
Data
AGC time constant (sec�)
SSB/CW/RTTY
AM
00
OFF
OFF
01
0�1
0�3
02
0�2
0�5
03
0�3
0�8
04
0�5
1�2
05
0�8
1�6
06
1�2
2�0
07
1�6
2�5
08
2�0
3�0
09
2�5
4�0
10
3�0
5�0
11
4�0
6�0
12
5�0
7�0
13
6�0
8�0
•
RX HPF/LPF setting for each operating mode
Command: 1A 05 0001, 0004, 0007, 0010,
0015, 0016
X X X X
*The value of the HPF should be smaller than the LPF.
HPF (Lower edge)
00=Through
01 ~ 20=100 ~ 2000 Hz
LPF(Upper edge)
05 ~ 24=500~2400 Hz
25=Through
•
SSB/SSB-DATA transmission passband
width settings
Command: 1A 05 0019 ~ 0022
X
X
Higher edge
0= 2500 Hz
1= 2700 Hz
2= 2800 Hz
3= 2900 Hz
Lower edge
0= 100 Hz
1= 200 Hz
2= 300 Hz
3= 500 Hz
Lower edge
Higher edge
•
Split offset frequency setting
Command: 1A 05 0046
1 kHz digit: 0
~
9
100 Hz digit: 0 (fixed)
100 kHz digit: 0 ~ 9
10 kHz digit: 0 ~ 9
10 MHz digit: 0 (fixed)
1 MHz digit: 0 ~ 9
Direction:
00=+ direction
01=– direction
1
0
X
X
X
X
2
3
0
4
X
X