1. General Description

2. Safety Information

FMX 400 Series IR cameras are specially designed to take the body temperature of a 

person and to report the total number of persons scanned. The system has been widely 

applied for inspection services, and is available for adjunctive use in: hospitals, and sub-

acute healthcare settings public areas, i.e. airports.

• 

This device must be installed by qualified service personnel or system installation 

personnel.

• 

Do take precautions to prevent the lens from being worn, scratched or broken. Avoid 

touching the lens to prevent it from being damaged or getting dirty.

• 

Given that the uncooled thermal infrared image camera uses a very sensitive thermal 

sensor, under no circumstances (powered on or off) should the lens be pointed 

directly at a strong radiation source (such as sun, direct or reflected laser beam, etc.), 

otherwise permanent damage will be caused to the uncooled thermal imager.

• 

This product is a precise electronic device that must be handled with care during use, 

storage, and transportation to prevent dangerous actions such as the device being hit 

by external force, or falling from heights.

• 

During transportation and storage, the ambient temperature must not be lower than 

-25 °C, and the original packaging box must be used during transportation.

• 

Prior to start of the device, make sure that the power supply is properly connected. If 

the power supply is connected incorrectly, the device may be damaged.

• 

Do not place any objects on the power cord, and do not place the device where the 

power cord can be easily touched.

• 

If the device operates abnormally, please contact the supplier and do not dismantle 

the device on your own.

• 

Do not drop or throw the device.

• 

Do not put the product into a fire.

• 

It is recommended to calibrate the device annually.

3. Intended Use

FMX 400 Series IR cameras are designed for body surface temperature measurement of 

infants and adults without contacting the human body.

Содержание FMX 400 P Series

Страница 1: ...SE READ THIS MANUAL BEFORE SWITCHING THE UNIT ON IMPORTANT SAFETY INFORMATION INSIDE ICI cameras fall under US Federal Law and Export Control THIS DEVICE IS INTENDED FOR ADJUNCTIVE USE NOT MEANT FOR STANDALONE DIAGNOSTICS For more information contact us 409 861 0788 sales infraredcameras com www infraredcameras com ...

Страница 2: ...ATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND NOTWITHSTANDING ANY OTHER WARRANTY HEREIN ALL DOCUMENT FILES AND SOFTWARE ARE PROVIDED AS IS WITH ALL FAULTS ICI DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE THE SOFTWARE LICENSE AN...

Страница 3: ...ety Information 3 Intended Use 4 Technical Specifications 5 Structure 6 Package Contents 7 Installation Instructions 8 Computer Setup 9 Cleaning and Maintenance 10 Site and System Validation Checklist 11 Troubleshooting 12 About ICI Contents 4 4 4 5 6 7 8 13 14 15 18 20 ...

Страница 4: ... otherwise permanent damage will be caused to the uncooled thermal imager This product is a precise electronic device that must be handled with care during use storage and transportation to prevent dangerous actions such as the device being hit by external force or falling from heights During transportation and storage the ambient temperature must not be lower than 25 C and the original packaging ...

Страница 5: ...te 50 Hz NTSC PAL Dynamic Range 14 bit Temperature Range 0 C to 60 C Operation Range 0 C to 60 C Storage Range 20 C to 65 C Humidity 5 to 95 non condensing Accuracy 0 3 C Pixel Operability 99 Dimensions without lens 119 mm x 55 mm x 55 mm L x W x H 5 mm Power DC 110V 10 36 3 W Weight without lens 370 g Interface RJ 45 Ethernet Video raw data Emissivity Correction 0 01 to 1 0 IP Rating IP 54 Shutte...

Страница 6: ...FMX 400 P SERIES IR CAMERA USER MANUAL 6 5 Structure 5 1 Appearance 5 2 Definitions of Housing Interface 1 Coaxial plug interface 2 Analog I O reserved 3 RJ 45 Internet access 1 2 3 ...

Страница 7: ...ANUAL 7 6 Package Contents Coaxial Cable Power Adapter Ethernet Cable FMX Series IR Camera Software USB Drive Temperature Reference AC Power Cord ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION ...

Страница 8: ...o a tripod using the 20 mount Plug power cord into Temperature Reference A SELECT AN APPROPRIATE AREA FREE OF IMMEDIATE AIRFLOW FROM DOORWAYS AND AIR CONDITIONING VENTILATION SYSTEMS THE SELECTED AREA SHOULD HAVE A STABLE AMBIENT TEMPERATURE BETWEEN 20 C AND 24 C AND RELATIVE HUMIDITY RANGE FROM 10 TO 50 ...

Страница 9: ...RECT PATH OF PERSON S TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN USING A DIVIDING BARRIER WILL HELP KEEP TRIPODS SEPARATE FROM THE PATH D Mount the FMX Series IR Camera to a tripod using the 20 mount C Plug power cord into a 110 120V electrical outlet ...

Страница 10: ...adapter into barrel end of coaxial cable E F Plug Ethernet cable into the Ethernet port of the FMX Series IR Camera Plug the other end of the Ethernet cable into the Ethernet port of the computer ENSURE THE CAMERA LENS AND TEMPERATURE REFERENCE SOURCE ARE FACING EACH OTHER ON PARALLEL PLANES MAKE SURE CAMERA TARGET AREA IS FACING A NON REFLECTIVE BACKGROUND ...

Страница 11: ...RAPHIC FOR ILLUSTRATION PURPOSES ONLY ALLOW AT LEAST 45 MINUTES FOR THE TEMPERATURE REFERENCE SOURCE TO WARM UP THIS WILL PROVIDE THE MOST ACCURATE SKIN TEMPERATURE MEASUREMENTS SOFTWARE ARRIVES INSTALLED ON COMPUTERS AND TABLETS PURCHASED FROM ICI AS COMPLETE SYSTEMS AND IT WILL LAUNCH AUTOMATICALLY ON STARTUP AFTER THE SOFTWARE LAUNCHES THE USER SHOULD ENSURE THE TARGET ZONE IS IN VIEW OF THE CA...

Страница 12: ...val of glasses headwear and masks Read the current government guidance regarding the use of telethermographic systems for skin temperature measurements Additional information can be found by reading IEC 80601 2 59 2017 Medical electrical equipment Part 2 59 Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening and I...

Страница 13: ...et a gateway as this is a direct connection from the computer to the cameras with no router Be sure the static IP address is set by doing the following 1 Click on Windows icon 2 Click on Settings 3 Click on Network and Internet 4 Click on Ethernet 5 Click on Change Adapter Settings 6 Right click on Ethernet and choose properties 7 Double click on Internet Protocol Version 4 TCP IPV4 Properties 8 T...

Страница 14: ...ck the lens or use too much wiping liquid If the lens is still not clean replace the cloth and repeat operation 9 Cleaning and Maintenance SOFTWARE DISPLAYS BEST WITH 1920 X 1080 RESOLUTION OR ABOVE 8 3 Recommended System Requirements Processor i5 or above Quad Core or better RAM 4 GB or above OS Windows 8 8 1 10 Hard Drive 256 GB or above Resolution 1920 x 1080 Software arrives installed on compu...

Страница 15: ...reflected sunlight Warm or cold conductive airflow HVAC vents intakes Any radiant energy from electrical sources Direct or indirect lighting on individual being screened Room temperature is 20 C 24 C 68 F 75 F Relative humidity is within 10 50 10 2 The Screening Background Placement is parallel and perpendicular to screening camera At a distance of 12 feet Consists of a non IR reflective homogeneo...

Страница 16: ...t of measurement on the floor V X or a set of footprints The distance is unique to each screening system Ensure the line of sight from the Temperature Reference Source to the camera is never blocked by an individual entering or leaving the point of measurement The secondary screening area should be setup near the screening area 10 4 Typical traffic flow illustration 10 5 IR Camera Placement Level ...

Страница 17: ...n tripod or other stable stand in front of background and positioned for visibility within the frame of the image Temperature is set at 35 C 95 F or 37 C 98 6 F Warm up time is 15 minutes 10 7 Software Set up the software according to the instructions Documentation can be found online on the IR Flash STM web page under the Downloads section or at this address https infraredcameras com ir flash stm...

Страница 18: ...newer or different version of IR Flash STM software 11 2 Camera out of focus For FMX 400 cameras Adjust electronic focus with middle button Close and reopen software Try newer or different version of IR Flash STM software Restart computer 11 3 Temperature readings are incorrect or facial recognition is suboptimal Close and reopen software Check that software settings are correct Fixed temperature ...

Страница 19: ...ectly at camera lens not at an angle Camera is in focus Reconnect power to camera Temperature Reference Source Temperature Reference Source power switch is on Camera and Temperature Reference Source powered on for several minutes Ensure temperatures on back of Temperature Reference Source match Restart Computer Camera is away from direct sunlight or reflective light Plain background Try newer vers...

Страница 20: ...g Institute In addition to providing custom germanium silica and sapphire optics we also build windows for enclosures as well as custom pan and tilt units We can even provide customizable explosion proof systems Our knowledge and experience stems from years of using infrared imaging and temperature measurement instruments to provide solutions to managers engineers scientists inspectors and operato...

Отзывы: