Monitor Components

 

 

 

The Choice of Power Supply

 

1.

 

Battery powered mode:

 

6V DC 4×AAA batteries

 

2.

 

AC adaptor powered mode:

 

6V

 

1A

 

(Can be supplied by AC adaptor model

 

UE08WCP-060100SPA !)(Not Included)

 

 

 
 
 
 
 
 
 
 

 

DC POWER SOCKET

 

INQUIRY BUTTON

 

USER 1

 

USER 2

 

 

Please unplug the adaptor to depart from

 

the using utility power.

 

Note:

 

The adaptor interface is located on the right side of the monitor. Place NO obstacles

 

on the right side for easy pull-off adaptor.

 

 

 
 
 
 

 

Component list of

 

pressure measuring system

 

1 Cuff

 

2 Air pipe

 

3 PCBA

 

4 Pump

 

5 Valve

 

LCD DISPLAY

 

 

 

BATTERY  COMPARTMENT

 

Installing and Replacing the Batteries

 

1. Open the battery door.

 

2. Insert the batteries according to the polarity

 

indications.

 

3. Close the battery door.

 

 

 

List

 

1.Blood Pressure Monitor

 

 

 

3. 4×AAA batteries

 

 

6

 

 

 

2.Cuff (Type BF applied part) (22cm-32cm)

 

(Please use iChoice authorized cuff.

 

The 

size of the actual cuff please refer to

 

the 

label on the attached cuff.)

 

 
 

4.User manual

 

 

7

 

CAUTION

 

In order to achieve the best performance and protect your monitor,

 

please use the authorized / specified battery and power adaptor.

 

Replace the batteries under following circumstances:

 

displays on the LCD.

 

The LCD display dims.

 

When powering on the monitor, the LCD doesn’t light up.

 

CAUTION

 

Remove batteries if the device is not likely to be used for some time.

 

Worn batteries are harmful to the environment. Do not dispose with daily garbage.

 

Remove the old batteries from the device following your local recycling guidelines.

 

Do not dispose of batteries in fire. Batteries may explode or leak.

 

AC adaptor

 

CUFF

 

AIR PIPE

 

AIR CONNECTOR PLUG

 

INTRODUCTION 

BEFORE YOU START

 

Содержание LS805-B

Страница 1: ...Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems Arm Type Contains FCC I...

Страница 2: ...the Records Delete the Records Data Transmission INFORMATION FOR USER 15 Tips for measurement Maintenance ABOUT BLOOD PRESSURE 17 What are systolic pressure and diastolic pressure What is the standar...

Страница 3: ...acemaker or defibrillator 2 The device is not intended to be a diagnostic device Contract your physician if hypertensive values are indicated Measurement Principle This product uses the Oscillometric...

Страница 4: ...continuous monitoring during medical emergencies or operations Otherwise the patient s arm and fingers will become anaesthetic swollen and even purple due to a lack of blood Please use the device und...

Страница 5: ...ttery door List 1 Blood Pressure Monitor 3 4 AAA batteries 6 2 Cuff Type BF applied part 22cm 32cm Please use iChoice authorized cuff The size of the actual cuff please refer to the label on the attac...

Страница 6: ...ss Query button to change the numeral Each press 4 Repeat steps 2 and 3 to confirm the MINUTE Then the monitor diverts to MONTH and DAY setting MONTH DAY 5 Repeat steps 2 and 3 to confirm MONTH and DA...

Страница 7: ...cuff s air pipe into the interface located on the right side of the monitor 2 As pictured on the right wear the cuff on your upper arm 3 Tighten the cuff up Make sure the cuff is fixed 2 to 3 centime...

Страница 8: ...ther user button to switch to display another user s measurement data 4 When User 2 has no record the LCD will display just like the picture on the right 5 Press User 1 User 2 button to turn off the m...

Страница 9: ...device 3 If the data transmission fails the symbol will remain The pending measurement data will be transmitted to your mobile device when next measurement is complete Within 1 hour after dinner or dr...

Страница 10: ...uideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mm Hg Diastolic Blood Pressure 85 mm Hg Irregular Heartbeat Detector An irregular heartbeat is detected when a heartbeat rhythm varies...

Страница 11: ...breaths before beginning will be better for measuring Advice Relax yourself for 4 5 minutes until you calm down It is ok for both arms but there will be some different results for different people We...

Страница 12: ...ad Haidian District 100143 Beijing P R China Complied Standards List 21 Risk Management ISO 14971 2007 Labeling EN 980 2008 User Manual EN 1041 2008 Generl Requirements for Safety IEC 60601 1 2005 A1...

Страница 13: ...electronic equipment may be affected RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable Guidance and manu...

Страница 14: ...d below The customer or the user of the device should assure that it is used in such an environment IMMUNITY test IEC 60601 TEST LEVEL Complia nce level Electromagnetic environment guidance Conducted...

Отзывы: