22
Installation method
Electrical connection
1. Supply AC 1PH 220V-240V electricity
to an additional power distribution
box with an earth leakage circuit
breaker of a capacity of more than
30 A is individually installed.
2. Remove the front panel at the
bottom front and remove the
control box cover.
3. Connect the 3C x 4.0
㎟
cable at the bottom of the control box to the terminal block
Electrical connections should be performed by an electrical technician
to make sure that each wire is correctly connected. If the connection is
wrong, it can cause explosions or ignition of the PCB in the product
and electrical shocks o
r fires
TERMINAL BLOCK
GROUND
For your
information
※
Maintain space of 50cm or more each between
the walls and the right and rear sides 20cm
or more between the left of the system.
50cm
20cm
50cm