SERVICE MANUAL
29
c) Remove the back metal lid and the top panel (if it need be to make easier the cleaning
operations).
d) Remove the auxiliary pipe for drain operations near the pump and empty the water tray.
Return it to their original position to avoid water spill.
e) Prepare a solution of an appropriate product for the cleaning of ice machines (lime). Do
not use hydrochloric acid. We recommend the use of any NSF approved scale removal
product prepared according to the manufacturer’s instructions.
f) Fill water tray with the solution
g) Disconnect power
. Turn on the machine pushing SW3
(see picture). Let solution stand for
30-40 minutes and then switch off the machine. Disconnect power
Pipe
for
drain
Water tray
Содержание FDHD Series
Страница 19: ...SERVICE MANUAL 19...
Страница 27: ...SERVICE MANUAL 27 6 Refrigeration diagram...
Страница 37: ...SERVICE MANUAL 37 8 TECHNICAL SPECIFICATIONS NG UNDER COUNTER MODULAR Z X Y X Z Y...