SERVICE MANUAL
16
10
Safety high pressure switch trip function.
ON= automatic reset (minimum stop 30 min.)
OFF= manual reset (power OFF-ON)
11
Timeout alarms operation
ON = activated
OFF = unactivated
12
Software selection.
Important: Always OFF for FDHD models
ICE / WATER TIMER SETTING
SW1
TF (MIN)
SW1
TW (SEG)
1
2
3
4
5
6
7
OFF
OFF
OFF
OFF
4
OFF
OFF
OFF
30
ON
OFF
OFF
OFF
6
ON
OFF
OFF
40
OFF
ON
OFF
OFF
8
OFF
ON
OFF
50
ON
ON
OFF
OFF
10
ON
ON
OFF
60
OFF
OFF
ON
OFF
12
OFF
OFF
ON
70
ON
OFF
ON
OFF
14
ON
OFF
ON
80
OFF
ON
ON
OFF
16
OFF
ON
ON
90
ON
ON
ON
OFF
18
ON
ON
ON
100
OFF
OFF
OFF
ON
20
ON
OFF
OFF
ON
22
OFF
ON
OFF
ON
24
ON
ON
OFF
ON
26
OFF
OFF
ON
ON
28
ON
OFF
ON
ON
30
OFF
ON
ON
ON
32
ON
ON
ON
ON
34
4.2.- ALARMS
They detect operational malfunctions. They are indicated with the flashing status Leds LE1-4.
During some alarms a second operation retry attempt is carried out and if repeated again, the machine
will stop. Signaling should be indicated since the first failure occurs. If the second retry attempt is ok, the
signaling will switch off.
In case that a machine stop has been caused by alarm, the reset is done by switching OFF and ON the
main switch. If the dip-switch 11 OFF, time alarms are not to be followed.