11
1. Position the storage bin in the selected per-
manent location.
Criteria for selection of location include:
a) Minimum room temperature 10°C (50°F)
and maximum room temperature 40°C
(100°F).
b) Water inlet temperatures: minimum 5°C
(40°F) and maximum 35°C (90°F).
c) Well ventilated location for air cooled
models (clean the air cooled condenser at
frequent intervals).
d) Service access: adequate space must be
left for all service connections through the
rear of the ice maker. A minimum clearan-
ce of 15 cm (6") must be left at the sides of
the unit for routing cooling air drawn into
and exhausted out of the compartment to
maintain proper condensing operation of
air cooled models.
2. Level the Storage Bin Assy in both the left to
right and front to rear directions by means of
the adjustable legs.
3. On D Series Storage Bin inspect its top
mounting gasket which should be flat with no
wrinkles, to provide a good sealing when the
KF Top Cover is installed on top of it.
4. Place the KF Top Cover on top of Storage bin
using care not to wrinkle or tear the gasket.
5. On the UD Series Storage Bin unloose the
screws securing the S.S. Top Cover to the
storage bin and remove it.
6 Lay out on the bin top the plan of the ice
machine as it will be located on the bin and
cut an opening in the bin top for the ice drop
area; cover the edges of the opening with
vinyl tape.
7 Install the gasket-on the bin top-around ice
drop opening of the bin top; apply sealant
along the inside of the gasket.
8 Position and install the four aluminium front to
rear stiffeners (U shaped) paying attention to
the guideline shown on the drawing.
9 Install the bin top in its position onto the bin
top by:
- place the rear side of top against rear
edge of the bin
- lower the front of the top onto the stiffeners
- re-fit the screws previously removed as
per step 5
10Install the Modular Flaker or Superflaker onto
the Top Cover of storage bin pay attention to
match the ice chute with the Bin Top ope-
ning.
D. ELECTRICAL CONNECTIONS
See data plate for current requirements to
determine wire size to be used for electrical
connections. All icemakers require a solid earth
wire. All ice machines are supplied from the fac-
tory completely pre-wired and require only elec-
trical power connections to the wire cord provi-
ded at the rear of the unit.
Make sure that the ice machine is connected to
its own circuit and individually fused (see data
plate for fuse size).
The maximum allowable voltage variation
should not exceed -10% and +10% of the data
plate rating. Low voltage can cause faulty func-
tioning and may be responsible for serious
STIFFENER
CUT GASKET HERE
BIN WALL GAKET
TOP SHELL
NOTE.
Bin wall gasket must be cut to clear
the stiffener ends as shown on drawing. Do
not put any stiffeners crossing the ice drop
opening.
Содержание F 125C
Страница 17: ...15...
Страница 35: ...35 WIRING DIAGRAM F 80C Air cooled 220 240 50 1...
Страница 36: ...36 WIRING DIAGRAM F 80C Water cooled 220 240 50 1...
Страница 37: ...37 WIRING DIAGRAM F 125C Air water cooled 220 240 50 1...
Страница 38: ...38 WIRING DIAGRAM F 120 F 200 Air water cooled 220 240 50 1...
Страница 39: ...39 WIRING DIAGRAM SF 300 SF 500 Air water cooled 220 240 50 1...
Страница 40: ...40 WIRING DIAGRAM SF 500 Air water cooled 400 50 3...
Страница 41: ...41 WIRING DIAGRAM SFN 1000 Air water cooled 400 50 3...
Страница 47: ......