Rev AA
Troubleshooting 6-18
ICE Vulcan Service Manual
LED Color
Status
Action Required
Bright Green
Label gap is detected
No operator
action required
Table 6-4: LED Status (Continued)
CLARiTY Error Messages
Table 6-5 provides the faults and warnings related to job design.
For complete list of faults and warnings refer to Integra Operator Manual.
Error No.
Error Description
Remedial Actions
Status
E5005
SlotSensorDetection
‘Dancer Arm Fault’
- The dancer arm
has failed to return
to its home
position.
•
Ensure the dancer arm is free to move.
This fault may be caused by an obstructed
dancer arm, or a faulty dancer arm home
position sensor. You can view the sensor
state at
Tools > Diagnostics > Printhead >
Inputs
.
•
If the problem persists, please call your
local service representative. The machine will
not run until this fault is resolved. Once
resolved and ready, press the ‘Clear’ button
below.
Fault
E5008
IntegraMotor
VoltsOutOfRange
‘Label Drive Fault’ -
The label drive motor
power safety system
has detected that the
motor volts are
outside the working
range.
•
Power the machine off and on to see if
the problem persists. This error can also be
caused by a faulty motor, a faulty main PCB
or a faulty power supply.
•
Please
call
your
local
service
representative for further support. The
machine will not run until this fault is
resolved.
Fault
Table 6-5: CLARiTY Error Messages
Содержание vulcan
Страница 1: ...ICEVulcanServiceManual Vulcan Service Manual ...
Страница 20: ...Equipment Safety Guidelines 2 5 ICEVulcan ServiceManual manual ...
Страница 33: ...Labeller 3 8 ICEVulcan ServiceManual Figure 3 9 Dancer Arm Sensor PCB ...
Страница 53: ...Installing the Label Applicator 4 8 ICEVulcan ServiceManual 2 1 1 Caster 2 Feet Figure 4 2 Caster and Feet ...
Страница 60: ...Installing the Label Applicator 4 13 ICEVulcan ServiceManual place Use an adjustable wrench ...
Страница 66: ...Installing the Label Applicator 4 19 ICEVulcan ServiceManual Figure 4 16 Right Hand Webbing Diagram ...
Страница 144: ...Rev AA Troubleshooting 6 31 ICEVulcan ServiceManual Table 6 5 CLARiTY Error Messages Continued ...
Страница 168: ...Rev AA Printhead Assembly 7 20 ICEVulcan ServiceManual Table 7 31 Printhead Cable Guide ...
Страница 173: ...Rev AA Printhead Assembly 7 23 ICEVulcan ServiceManual Table 7 39 Ribbon Drive Motor ...
Страница 219: ...B 4 Rev AA ICEVulcan ServiceManual LabelRepeat Distance 500 5 5000 Table B 1 CLARiTY Configuration Manager Continued ...
Страница 235: ...C 2 Main Board Test Points Rev AA ...