PROBLEM
CAUSE
SOLUTION
LITTLE OR NO SOLUTION
FLOW TO THE FLOOR
Solution Tank Empty
Fill Solution Tank
Solution Flow Turned
Off or Set Too Low
Turn On or Increase Flow Setting
Solution Strainer Plugged
Clean Solution Strainer
Solution Hoses Obstructed
Clear Obstruction from Hose
Solution Solenoid Valve
Obstructed or Stuck
Clean or Replace
Vent Hole in Solution
Tank Lid Obstructed
Clear Obstruction from Vent Hole
NO POWER TO MACHINE
Battery Disconnected
Check All Battery Cable Connections
Emergency Shut-Off
Activated
Reset
Battery Terminals Corroded
Clean Connections
Faulty Main Contactor
Replace Contactor
Faulty Key Switch
Replace Switch
LITTLE OR NO PROPEL
Low Battery Charge
Charge Batteries
Wheels Spin
Decrease Brush Pressure
Controller Overheated
Allow Cool Down Period. Adjust Brush if Needed
Loose Connection
Check Motor Wires and Connection
WATER TANK READS
EMPTY WHEN IT
IS NOT EMPTY
Water Tank Float
Switch Is Damaged
Repair / Replace Float Switch
Loose Connection
Check Wires And Connection
BATTERY LIFE IS
SHORTER THAN
EXPECTED
Low Battery Charge
Charge Batteries
Batteries are Old and
Need to be Replaced
Replace Batteries
BATTERIES NOT
CHARGING
Lead Acid Batteries Allowed
to Completely Discharge
Polarity Flipped. Allow 24-48 Hours
Charge Time to Restore Battery
Battery Charger
Malfunctioning
Repair/Replace Battery Charger
Wall Outlet Not
Providing Voltage
Restore Outlet Power