INSTALLING AND REMOVING BRUSHES OR PADS
Before installing brushes or pads, ensure Brain-enabled scrubber is off.
1. The Brain-enabled scrubber must not be in autonomous
mode. In addition, check to ensure that all machine
parts are raised off the fl oor
2. If using the pad driver, fi rst attach the appropriate pad
to the pad driver surface.
3. Remove the side squeegee assembly before installing
brushes. Align the pad driver or brush under the motor
hub and push it upward to engage.
4. To remove the pad driver or brush – ensure machine
is off and scrub head is in the raised position. Remove
the side squeegee assembly (Machine Components
#6), and push the edge of the brush downward.
MOUNTING SIDE AND REAR SQUEEGEE ASSEMBLIES
1. Press the one-touch button to turn off the scrubber
functions and ensure the squeegee assembly and
scrub head are off the fl oor. Turn key to the off position.
2. Mount the squeegee assembly to the squeegee pivot
bracket. Make sure the knobs are completely seated
into the slots before securing them. Hand tighten only.
3. Connect the vacuum hose (Machine Components #29) to the squeegee
assembly. Loop the hose by using the hose clip provided.
4. Check the squeegee blades for proper adjustment. (See “How to Adjust” instructions for further guidance).