ICE RS26, powered by Brain OS | Gen2, v1.1217 – Content Subject to Change
Brain Corporation
45
ADDITIONAL TIPS
PROBLEM
CAUSE
SOLUTION
POOR OR NO
WATER PICK-UP
Squeegee Out of Adjustment Adjust Squeegee
Debris Caught in Squeegee
Remove Debris
Worn Squeegee Blades
Rotate or Replace Squeegee Blades
Vacuum Hose Clogged
Clear Obstruction from Hose
Vacuum Hose Disconnected
from Squeegee or
Recovery Tank
Reconnect Vacuum Hose
Vacuum Hose Damaged
Replace Vacuum Hose
Recovery Tank Not Sealed
Place Recovery Tank Dome on Tank. Replace Damaged Gasket
Foam Filling Recovery Tank
Empty Recovery Tank. Use Less or
Different Detergent. use Defoamer
VACUUM MOTOR
DOES NOT RUN OR
RUNS SLOWLY
Recovery Tank Full
Drain Recovery Tank
Recovery Tank Float
System Dirty
Clean Float System
Circuit Breaker Tripped
Reset Circuit Breaker
Loose Connection
Check Motor Wires and Connections
Faulty Vacuum Switch
Replace Switch
Worn Vacuum
Motor Brushes
Replace Brushes or Pads
POOR SCRUBBING
PERFORMANCE
Debris Caught in
Scrub Brushes
Remove Debris
Worn Brushes or Pads
Replace Brushes or Pads
Improper Detergent,
Brush or Pad Used
Contact Equipment or Application Specialist
Low Scrub Down Pressure
Increase Brush Pressure
Low Battery Charge
Charge Batteries
BRUSH MOTORS DO NOT
RUN, OR RUNS SLOWLY
Circuit Breaker(S) Tripped
Reset Circuit Breaker(s)
Loose Connection
Check Motor Wires and Connection
Faulty Brush Motor
Contactor
Replace Contactor
Worn Brush Motor Brushes
Replace Brushes, Check Commutator