24
ICE iS1100
OPERATOR
TROUBLESHOOTING
Trouble
Possible cause
Remedy
The machine does not start when
turning the ignition key to “I”.
The battery connector (44) is
disconnected.
Connect the battery connector.
The fM fuse in the holder (54) is open. Replace the fM fuse.
The battery charger cable is connected
to the electrical mains.
Disconnect the battery charger cable
from the electrical mains.
The main brush does not work.
The main brush microswitch faulty.
Replace the main brush microswitch.
The side brushes do not operate. The main brush is not lowered.
Lower the main brush.
The side brush microswitch faulty.
Replace the side brush microswitch.
The machine operates only when
stationary, otherwise battery level
indicator begins flashing,.
The batteries are discharged.
Charge the batteries.
If the problem persists, replace the
battery.
The battery autonomy is low.
The batteries are dead.
Replace the batteries.
The battery capacity is low.
Buy batteries with higher capacity
(see the Technical Data paragraph).
SCRAPPING
Have the machine scrapped by a qualified scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly
according to the Law in force:
- Batteries - Engine oil
- Polyester dust filter - Main and side brushes
- Plastic hoses and components - Electrical and electronic components (*)
(*) Refer to the nearest ICE Center especially when scrapping electrical and electronic components.
ALARMS
Active alarms are shown on the display.
Alarm #id
Meaning
Action
f01:Seat Empty
No sit in the seat or Seat circuit open
Sit in the operator seat or Check circuit
f04:Vac Mtr O.L RE-START
Vac Mtr ammeter protection
Verify vacuum motor working current value
f05:Main Bru Mtr O.L RE-START
Main bru mtr ammeter protection
Verify main bru motor working current value
f06:Side Bru Mtr O.L RE-START
Side bru mtr ammeter protection
Verify side bru motor working current value
f07:Propel Mtr O.L
Propel Motor ammeter protection
Verify Propel Motor current value
f10:Batt Low Charge batt
Battery is low
Charging the battery
f11:Batt Very Low Charge batt
NOW!!
Battery is very low
Charging the battery
f12:Brake Wiring Error
Brake circuit open
Check brake wirings and circuit
f13:Release foot Pedal
Steping the foot pedal when starting
machine
Release the foot pedal when turn on the machine
f14:Replace Brake Assy
Brake circuit short
Check brake wirings and circuit
f16:Control Unit Overheat! Wait
Over Temp or Control Unit fault
Verify motor working current value or Change
Control Unit
f17:Replace Control Unit
Temp. Sensor failure
ChangeControl Unit
f18:Replace foot Pedal Assy
foot Pedal Sensor failure
Verify pedal wirings and pedal sensor
f20:Check Main Brush Motor
Main Motor error or circuit open
Verify wirings and main brush motor
f21:Check Vac Mtr
Vac Motor error or circuit open
Verify wirings and vac motor
f24:Check Propel Motor
Propel Motor error or circuit open
Verify wirings and propel motor
f25:Check Side Brush Motor
Side Brush Motor error or circuit open
Verify wirings and side brush motors
f40:Check Proximity Sw
Sw Sensor failure
Change Sw Sensor
f42:Replace Control Unit
Relay Contact error
Change Control Unit
f43:Turn Dead Sw Off RE-START
Emergency stop button be actived or
circuit open
Reset emergency stop button,restart the machine
or check circuit
f44:Replace Control Unit
Control Unit fault
Change Control Unit
f45:Return Control Unit
Control Unit fault
Change Control Unit
f46:Return Control Unit
Control Unit fault
Change Control Unit
f47:Replace Control Unit
Control Unit fault
Change Control Unit
f48:Return Control Unit
Control Unit fault
Change Control Unit
https://harrissupplyind.com - To Order Parts Call 608-268-8080