ICE iS1100
17
OPERATOR
MAIN BRUSH HEIGHT CHECK
AND ADJUSTMENT
NOTE:Brushes with harder or softer bristles are
available. This procedure is applicable to all types of
brushes.
1) Check the main brush distance from the floor
as shown below:
-
Drive the machine on a level floor.
-Keep the machine stationary, lower the main brush and
turn it on for a few seconds.
-Stop and lift the main brush, then move the machine and
switch it off.
-Check that the main brush print (A, fig. 1), along its
length is 0.8 to 1.6 in (2 to 4 cm) wide.
If the print (A) is not within specifications, adjust the brush
height as shown in step 2.
2) Turn the ignition key (71) to “0”.
3) Open the body(5)
4) Loosen the knob (A, fig. 2) on the left side of the
machine.
5) Turn the knob (B, fig. 2) and remind that:
-It must be screwed to lift the brush;
-It must be unscrewed to lower the brush.
After the adjustment, hold the knob (B) and
tighten the knob (A).
6) Perform step 1 again to check the proper
adjustment of the main broom height.
8) When the brush is too worn to be adjusted, replace
it as shown in the next paragraph.
CAUTION!
If the main broom print
is excessive(larger than 1.6 in (4 cm)),
the machine regular operation is affected
and the moving or electrical parts can
overheat, thus reducing machine life.
Pay careful attention when performing
the above-mentioned checks, and
always use the machine according to the
indicated conditions.
Figure1
Figure2
https://harrissupplyind.com - To Order Parts Call 608-268-8080