background image

EF and EMF Series

 

 

 Freight Claim Procedure 

 

Page iii 

 

Important! 

 

Inspect Promptly 

This merchandise has been carefully inspected and packed in accordance with the carrier’s packing specifications.  
Responsibility for safe delivery has been assumed by the carrier. If loss or damage occurs, you as the consignee must 
file a claim with the carrier and hold the container for carrier’s inspection. 
 

Visible Loss or Damage 

Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and 
signed by the carrier’s agent.  Claim should be filed on a form available from the carrier. 
 

Concealed Loss or Damage 

If loss or damage does not appear until merchandise has been unpacked, make a written request for inspection by the 
carrier within 15 days of the delivery date.  Then file a claim on a form from the carrier. 
 

File Claim Without Delay 

 

Do Not Return Damaged Merchandise to ICE-O-Matic 

 

 

Содержание Series 250 through 2306

Страница 1: ...Installation Start Up and Maintenance Manual EF and EMF Flaked Ice Machines Series 250 through 2306 ICE O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081178 01 Date 1 06 Rev C...

Страница 2: ...1...

Страница 3: ...e Department E Mail Tech service iceomatic com Telephone Numbers Any Service communication must include 800 423 3367 All Departments Model Number 888 349 4423 Technical Assistance Only Serial number 3...

Страница 4: ...Number and Serial Number Format Page 1 Installation Guidelines Page 2 3 Remote Condenser Guidelines Page 4 Electrical and Plumbing Requirements Page 6 How the Machine Works Page 9 Start Up Procedure...

Страница 5: ...for carrier s inspection Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent Cla...

Страница 6: ...acts of God This warranty is valid only when installation service and preventive maintenance are performed by a Company authorized distributor a Company authorized service agency or a Company Regional...

Страница 7: ...r Flaker Uses HFC Refrigerant This format is 14 characters long and begins with a date code followed by the ICE O Matic identifier and then a sequential number This is an entirely numerical serial num...

Страница 8: ...ith the ice machine Clearance Requirements Self contained air cooled ice machines must have a minimum of 6 inches 15cm of clearance at the sides of the ice machine for proper air circulation Stacking...

Страница 9: ...and fuse size according to the specifications listed on the serial data plate located on the rear of the ice machine cabinet 2 Supply power to the ice machine on a dedicated electrical circuit Only th...

Страница 10: ...nduit The penetration should be within two feet of where the condenser will be located A roof jack must be installed at the penetration Installation Guidelines Ambient operating temperatures 20 F 28 9...

Страница 11: ...ration Installation Guidelines Ambient operating temperatures 20 F 28 9 C to 120 F 48 9 C Condenser Airflow Condensers must have a vertical airflow ICE Machine Model Number Remote Condenser Model Numb...

Страница 12: ...EF and EMF Series Electrical and Plumbing Requirements Page 6 Electrical and Plumbing Requirements 32 38 and 48 inch Cabinets SIDE VIEW REAR VIEW FRONT VIEW ICE O MATIC TOP VIEW...

Страница 13: ...EF and EMF Series Electrical and Plumbing Requirements Page 7 Electrical and Plumbing Requirements EMF 400 800 1000 Air Water and Remote...

Страница 14: ...EF and EMF Series Electrical and Plumbing Requirements Page 8 Electrical and Plumbing Requirements EMF2300 Air Water and Remote...

Страница 15: ...r is delayed for 2 to 4 minutes After the compressor delay period the compressor and condenser fan motor air cooled machines only starts causing the temperature of the evaporator to drop The water in...

Страница 16: ...l well at the bottom of the evaporator The Safety Control turns the machine off if the evaporator temperature reaches approximately 30 F 1C The Safety Control can be adjusted by turning the adjusting...

Страница 17: ...ere will be a compressor delay of 2 to 4 minutes after turning the machine on If ice is touching the bin control thermal well for more than 3 minutes and the machine has not shut off turn the adjustin...

Страница 18: ...rmed a minimum of every 6 months Local water conditions may require that cleaning be performed more often 2 Check the water level in the float reservoir 3 Clean the condenser air cooled machines to in...

Страница 19: ...1 gallon 3 75l of approved U S FDA 21 CFR 178 1010 food equipment sanitizer to form a solution with 100 200 ppm free chlorine yield Reserve about 1 3 gallon for step 13 below 8 Turn the machine on an...

Страница 20: ...er the thin layer on the surface of stainless steel that protects it from corrosion 3 Don t use cleaners that use chlorine or chlorides Don t use chlorine bleach or products like Comet to clean the st...

Страница 21: ...all ice is out of the evaporator s 3 Place the ON OFF switch to the OFF position 4 Disconnect the tubing between the evaporator and float 5 Drain the water system completely 6 On water cooled machine...

Страница 22: ...________________________________________________________________________________ __________________________________________________________________________________________ ____________________________...