background image

 EF and EMF Series

 

 

 Start-Up Procedure

 

 

Page 11 

 

Check bin control for proper operation

 

 

The bin control is used to shut the machine off when the bin fills with ice.  The bin control must be checked upon 
installation or initial start-up and when performing maintenance.  

Adjustments are not covered under warranty. 

 
With the machine running and making ice, hold ice against the brass thermal well that houses the bin control capillary 
tube.  The brass thermal well is located on the inside of the down chute on the EMF models and in the storage bin on 
the EF models.  The machine should shut off in approximately 2 minutes.  Remove the ice from the thermal well and 
the machine should come back on within 2 minutes.  The bin control adjusting screw can be accessed through a hole 
in the control box.  Note: On some models there will be a compressor delay of 2 to 4 minutes after turning the machine 
on. 
 

If ice is touching the bin control thermal well for more 
than 3 minutes and the machine has not shut off, turn 
the adjusting screw counter-clockwise approximately 
1/8 turn and recheck. 

 
 
 
 
 
 
 
 
 
 

Check secondary bin control for proper operation

 

 
EF Series Flakers: With the machine off, reach inside the bin and push up on the white diaphragm located at the top of 
the bin.  The switch contacts should change before the diaphragm is lifted ½ inch.  Contacts should change again 
when the diaphragm is 
released.  To adjust switch, 
remove cabinet top and 
move switch to proper 
position. 
 
 
 
 
 
 
 
 
 
 
 
EMF Series Flakers: With the machine off, lift up slightly on the 
white diaphragm located on top of the down chute.  The switch 
contacts should change before the actuator is lifted more than ½ 
inch.  Contacts should change again when the diaphragm is 
released.  To adjust switch, remove cabinet top and move 
switch to proper position. 
 
 
 
 

Check for water leaks and excessive noise.

 

 
 
 
 
 
 

Содержание Series 250 through 2306

Страница 1: ...Installation Start Up and Maintenance Manual EF and EMF Flaked Ice Machines Series 250 through 2306 ICE O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081178 01 Date 1 06 Rev C...

Страница 2: ...1...

Страница 3: ...e Department E Mail Tech service iceomatic com Telephone Numbers Any Service communication must include 800 423 3367 All Departments Model Number 888 349 4423 Technical Assistance Only Serial number 3...

Страница 4: ...Number and Serial Number Format Page 1 Installation Guidelines Page 2 3 Remote Condenser Guidelines Page 4 Electrical and Plumbing Requirements Page 6 How the Machine Works Page 9 Start Up Procedure...

Страница 5: ...for carrier s inspection Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent Cla...

Страница 6: ...acts of God This warranty is valid only when installation service and preventive maintenance are performed by a Company authorized distributor a Company authorized service agency or a Company Regional...

Страница 7: ...r Flaker Uses HFC Refrigerant This format is 14 characters long and begins with a date code followed by the ICE O Matic identifier and then a sequential number This is an entirely numerical serial num...

Страница 8: ...ith the ice machine Clearance Requirements Self contained air cooled ice machines must have a minimum of 6 inches 15cm of clearance at the sides of the ice machine for proper air circulation Stacking...

Страница 9: ...and fuse size according to the specifications listed on the serial data plate located on the rear of the ice machine cabinet 2 Supply power to the ice machine on a dedicated electrical circuit Only th...

Страница 10: ...nduit The penetration should be within two feet of where the condenser will be located A roof jack must be installed at the penetration Installation Guidelines Ambient operating temperatures 20 F 28 9...

Страница 11: ...ration Installation Guidelines Ambient operating temperatures 20 F 28 9 C to 120 F 48 9 C Condenser Airflow Condensers must have a vertical airflow ICE Machine Model Number Remote Condenser Model Numb...

Страница 12: ...EF and EMF Series Electrical and Plumbing Requirements Page 6 Electrical and Plumbing Requirements 32 38 and 48 inch Cabinets SIDE VIEW REAR VIEW FRONT VIEW ICE O MATIC TOP VIEW...

Страница 13: ...EF and EMF Series Electrical and Plumbing Requirements Page 7 Electrical and Plumbing Requirements EMF 400 800 1000 Air Water and Remote...

Страница 14: ...EF and EMF Series Electrical and Plumbing Requirements Page 8 Electrical and Plumbing Requirements EMF2300 Air Water and Remote...

Страница 15: ...r is delayed for 2 to 4 minutes After the compressor delay period the compressor and condenser fan motor air cooled machines only starts causing the temperature of the evaporator to drop The water in...

Страница 16: ...l well at the bottom of the evaporator The Safety Control turns the machine off if the evaporator temperature reaches approximately 30 F 1C The Safety Control can be adjusted by turning the adjusting...

Страница 17: ...ere will be a compressor delay of 2 to 4 minutes after turning the machine on If ice is touching the bin control thermal well for more than 3 minutes and the machine has not shut off turn the adjustin...

Страница 18: ...rmed a minimum of every 6 months Local water conditions may require that cleaning be performed more often 2 Check the water level in the float reservoir 3 Clean the condenser air cooled machines to in...

Страница 19: ...1 gallon 3 75l of approved U S FDA 21 CFR 178 1010 food equipment sanitizer to form a solution with 100 200 ppm free chlorine yield Reserve about 1 3 gallon for step 13 below 8 Turn the machine on an...

Страница 20: ...er the thin layer on the surface of stainless steel that protects it from corrosion 3 Don t use cleaners that use chlorine or chlorides Don t use chlorine bleach or products like Comet to clean the st...

Страница 21: ...all ice is out of the evaporator s 3 Place the ON OFF switch to the OFF position 4 Disconnect the tubing between the evaporator and float 5 Drain the water system completely 6 On water cooled machine...

Страница 22: ...________________________________________________________________________________ __________________________________________________________________________________________ ____________________________...

Отзывы: