background image

 EF and EMF Series

 

 

 

General Maintenance

 

 

Page 12 

 

Electrical shock and/or injury from moving parts inside this machine 
can cause serious injury.  Disconnect electrical supply to machine 
prior to performing any adjustments or repairs. 
 
Failure to perform the required maintenance at the frequency specified 
will void warranty coverage in the event of a related failure.   
 

General Maintenance Procedure 
 

To insure economical, trouble free operation of your machine, it is recommended that the following maintenance be 
performed every 6 months. 

 

1.  Clean the ice-making section per the instructions on the next page.  Cleaning should be performed a minimum of 

every 6 months.  Local water conditions may require that cleaning be performed more often. 

 
2.  Check the water level in the float reservoir. 
 
3.  Clean the condenser (air-cooled machines) to insure unobstructed air flow. 
 
4.  Check for leaks of any kind: Water, Refrigerant, Oil, Etc. 
 
5.  Check the bin control for proper adjustment.   
 
6.  Check the secondary bin control for proper adjustment.   
 
7.  Check the water valve (water-cooled machines) for proper adjustment by measuring the water temperature at the 

outlet of the condenser.  It should be between 100

°

F and 110

°

F. (38

°

C and 43

°

C) 

 
8.  Check all electrical connections. 
 
9.  Oil the fan motor if the motor has an oil fitting.  (Self contained air-cooled models only) 
 

10.  Check the water filter (if applicable) and replace if dirty or restricted. 

 

11.   Check the safety control for proper adjustment. 

 

Содержание Series 250 through 2306

Страница 1: ...Installation Start Up and Maintenance Manual EF and EMF Flaked Ice Machines Series 250 through 2306 ICE O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081178 01 Date 1 06 Rev C...

Страница 2: ...1...

Страница 3: ...e Department E Mail Tech service iceomatic com Telephone Numbers Any Service communication must include 800 423 3367 All Departments Model Number 888 349 4423 Technical Assistance Only Serial number 3...

Страница 4: ...Number and Serial Number Format Page 1 Installation Guidelines Page 2 3 Remote Condenser Guidelines Page 4 Electrical and Plumbing Requirements Page 6 How the Machine Works Page 9 Start Up Procedure...

Страница 5: ...for carrier s inspection Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent Cla...

Страница 6: ...acts of God This warranty is valid only when installation service and preventive maintenance are performed by a Company authorized distributor a Company authorized service agency or a Company Regional...

Страница 7: ...r Flaker Uses HFC Refrigerant This format is 14 characters long and begins with a date code followed by the ICE O Matic identifier and then a sequential number This is an entirely numerical serial num...

Страница 8: ...ith the ice machine Clearance Requirements Self contained air cooled ice machines must have a minimum of 6 inches 15cm of clearance at the sides of the ice machine for proper air circulation Stacking...

Страница 9: ...and fuse size according to the specifications listed on the serial data plate located on the rear of the ice machine cabinet 2 Supply power to the ice machine on a dedicated electrical circuit Only th...

Страница 10: ...nduit The penetration should be within two feet of where the condenser will be located A roof jack must be installed at the penetration Installation Guidelines Ambient operating temperatures 20 F 28 9...

Страница 11: ...ration Installation Guidelines Ambient operating temperatures 20 F 28 9 C to 120 F 48 9 C Condenser Airflow Condensers must have a vertical airflow ICE Machine Model Number Remote Condenser Model Numb...

Страница 12: ...EF and EMF Series Electrical and Plumbing Requirements Page 6 Electrical and Plumbing Requirements 32 38 and 48 inch Cabinets SIDE VIEW REAR VIEW FRONT VIEW ICE O MATIC TOP VIEW...

Страница 13: ...EF and EMF Series Electrical and Plumbing Requirements Page 7 Electrical and Plumbing Requirements EMF 400 800 1000 Air Water and Remote...

Страница 14: ...EF and EMF Series Electrical and Plumbing Requirements Page 8 Electrical and Plumbing Requirements EMF2300 Air Water and Remote...

Страница 15: ...r is delayed for 2 to 4 minutes After the compressor delay period the compressor and condenser fan motor air cooled machines only starts causing the temperature of the evaporator to drop The water in...

Страница 16: ...l well at the bottom of the evaporator The Safety Control turns the machine off if the evaporator temperature reaches approximately 30 F 1C The Safety Control can be adjusted by turning the adjusting...

Страница 17: ...ere will be a compressor delay of 2 to 4 minutes after turning the machine on If ice is touching the bin control thermal well for more than 3 minutes and the machine has not shut off turn the adjustin...

Страница 18: ...rmed a minimum of every 6 months Local water conditions may require that cleaning be performed more often 2 Check the water level in the float reservoir 3 Clean the condenser air cooled machines to in...

Страница 19: ...1 gallon 3 75l of approved U S FDA 21 CFR 178 1010 food equipment sanitizer to form a solution with 100 200 ppm free chlorine yield Reserve about 1 3 gallon for step 13 below 8 Turn the machine on an...

Страница 20: ...er the thin layer on the surface of stainless steel that protects it from corrosion 3 Don t use cleaners that use chlorine or chlorides Don t use chlorine bleach or products like Comet to clean the st...

Страница 21: ...all ice is out of the evaporator s 3 Place the ON OFF switch to the OFF position 4 Disconnect the tubing between the evaporator and float 5 Drain the water system completely 6 On water cooled machine...

Страница 22: ...________________________________________________________________________________ __________________________________________________________________________________________ ____________________________...

Отзывы: