CLEANING/SANITIZING PROCEDURES
57
Cleaning Instruction for Ice-O-Matic CIM Series Ice Machines
Note: Proper cleaning of an ice machine requires two parts: descaling and sanitizing.
Descaling
should be scheduled at a minimum of twice per year but no more than once per month.
Descaling dissolves the mineral deposits on the evaporator and other surfaces. It removes scale, calcium, lime
scale and other mineral buildup. Ice-O-Matic requires a “nickel-safe” cleaner such as Nu-Calgon Nickel-Safe Ice
Machine Cleaner or equivalent diluted per manufacturer’s instructions.
Sanitizing
should be performed after each descaling but no more than once per month.
Sanitizing disinfects the machine and removes microbial growth including mold and slime. Ice-O-Matic requires
a sanitizer such as Nu-Calgon IMS-III or equivalent diluted per manufacturer’s instructions.
Please refer to
www.iceomatic.com
for approved chemical formulations and proper pH balance.
CAUTION: Do not mix cleaner (descaler) and sanitizer together.
Note: Electrical power will be ON when performing the following cleaning instructions.
1. Remove all ice from storage means to prevent any contamination of ice in storage.
2. Remove the front panel of the ice machine by loosening the two front panel screws with a Phillips head
screwdriver. Lift panel to remove.
3. Press and hold the POWER button for 3 seconds to initiate a harvest cycle (blue light will begin to flash for
Manual Harvest mode). This ensures there is no ice on the plate and the water is emptied from the sump.
4. Once the ice machine has completed its harvest cycle, the POWER light will go to solid red (OFF mode).
5. Remove the upper evaporator cover and leave the lower curtain.
Power Button
Clean Button
Top Cover
Evaporator cover
(Slide up and Lift Off)
Содержание CIM0320
Страница 3: ...ELEVATION SERIES CIM CUBERS TABLE OF CONTENTS ...
Страница 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 33 ...
Страница 51: ...ELEVATION SERIES CIM CUBERS EVAPORATOR REPLACEMENT 48 ...
Страница 66: ...ELEVATION SERIES WIRING DIAGRAM 63 CIM0325 0335 0435 0525 0535 0635 0835 and 1135 AIR AND WATER COOLED UNITS ...
Страница 67: ...ELEVATION SERIES WIRING DIAGRAM 64 CIM0530 0636 0836 1126 and 1136 REMOTE COOLED UNITS ...
Страница 68: ...ELEVATION SERIES WIRING DIAGRAM 65 CIM0535 0835 and 1135 REMOTE COOLED UNITS ...