ELEVATION SERIES CIM CUBERS
SEQUENCE OF OPERATIONS
10
SEQUENCE OF OPERATIONS
CONTROL BOARD - OFF STATUS
When power is initially applied to the unit, the LED’s on both the Push Pad and the Board POWER Button
will flash in sequence BLUE, then RED, then the WASH Button will flash YELLOW, followed by the POWER
Button LED will turn a solid RED, indicating the unit is in the OFF status as shown above.
The LED’s for the Curtain Switches (1 & 2), High Float Switch and Low Float Switch will be illuminated indi‐
cating closed circuits. Should the Curtains or Bin Thermostat (if added) be open, the unit will not start a
Freeze Cycle.
From an OFF status, the unit can start a CLEAN cycle, a FREEZE cycle or be put in the DIAGNOSTIC mode.
For Cleaning Instructions, see page 56. For more on the DIAGNOSTIC mode see page 30.
BROWN
BLUE
VIOLET
BLACK
RED
TAN
PINK
YELLOW
= Illuminated LED
WHITE
WHITE
BLUE w/ WHITE
BLUE w/ RED
BLUE
12V DC Switches
Line Voltage
Components
R1
R2
R3
R4
R5
R6