CONTROL BOARD - ANTI-SLUSH
During the first 3 cycles as the water temperature reaches 36 degrees F. the Water Pump will shut off for
20 seconds to reduce the possibility of slush developing in the Sump. After the first 3 cycles, Anti‐Slush
will only occur if the Sump water temperature reaches 28 degrees F.