ICCONS® GAS TOOL GT6-IXF USER MANUAL

damaged, disconnect the supply and stop 
charging the battery immediately. If cable 
or plug damaged, do not use for charging 
battery. Contact authorized service agent 
for replacement.

 - Keep the charger exhaust area clean 

and unblock to have the best cooling 
effect. Use dry cloth to clean the body 
and the contact of the charger while it 
disconnected with the main power.

 - Charge the battery in room temperature. If 

the temperature is less than 0°C or greater 
than 45°C will harm the performance or 
degrade the battery.

 - If the battery charger abnormally heats 

up or gives off fumes during charging, 
disconnect the power supply of the 
charger immediately.

4.2  Safety For Handling Battery

 - Do not short circuit the battery pack.
 - Do not pierce or open the battery pack.
 - Do not store the batteries at a temperature 

above 50°C.

 - Do not incinerate spent batteries.
 - Only charge one battery at a time.
 - Batteries and charging systems must be 

recycled or taken to a designated disposal 
area.

4.3  Battery Storage

 - Store the batteries in a cool and dry place.
 - Over-discharge will degrade the batteries 

capacity. Fully charged the batteries if 
stored for a long time. Recharge it in each 
3 months can help to compensate the self-
discharged and keep the battery in a good 
condition.

 - The charging systems should store at a 

place out of reach of Children. 

 - Always disconnect the batteries from tools 

or charger while stored.

 -

4  Use Of The Battery & 

Charging System

  

READ INSTRUCTIONS

CLASS II DEVICE

FOR INDOOR USE ONLY

TIME-LAG FUSE-LINK

DISPOSE SEPARATELY FROM 
HOUSEHOLD-TYPE WASTE

Introduction

 - The adaptor, charger and the battery 

are designed to operate together as one 
system. Only use the

 ‘ICCONS® Pty Ltd’

 

Adaptor & 

‘ICCONS® Pty Ltd’

 Charger for 

charging the 

‘ICCONS® Pty Ltd’

 Batteries. 

 - The charging system is intended to be 

used in covered areas. 

 - Do not expose it to rain or to excessive 

humidity. 

 - Do not recharge non-rechargeable 

batteries.

4.1  Before Charging

 - Arrange the supply cord appropriately 

to avoid unnecessary damage, avoid 
laying the supply cord across walkway or 
doorway.

 - When charging the battery pack, use 

a specified battery charger. Check the 
output and the polarity of the battery 
charger are match with the battery pack 
intended to charge.

 - Check the system before use. Maintenance 

and servicing are not required under 
normal conditions. Do not dismantled the 
battery charger or the battery pack.

 - If the battery pack or charger enclosure is 

Содержание GT6-IXF

Страница 1: ...190813 rev 1 USER MANUAL GT6 IXF GAS TOOL...

Страница 2: ...1 Symbols Used In This Operating Manual 3 2 General Safety Instructions 3 2 1 2 2 2 3 2 4 2 5 Introduction Safety Of The Fastening Tool Safety At Work Safety For Handling Fasteners Safety For Gas Ope...

Страница 3: ...Introduction Only those fasteners which are specified in the operating instructions shall be used in the tool The tool the fastener the fuel cell and the battery specified in the operating instructio...

Страница 4: ...Do not load the fasteners with the trigger and or work contacting element pressed Ensure that you use the correct length of fastener with the depth adjuster correctly set so that nails do not protrud...

Страница 5: ...Rail ADR RID UN code 2037 class 2 1 Sea IMDG UN code 2037 class 2 1 EmS F D S U Air IATA UN code 2037 class 2 1 Goods must be accompanied by a transport emergency card for road UN 2037 Transport by po...

Страница 6: ...lly charged the batteries if stored for a long time Recharge it in each 3 months can help to compensate the self discharged and keep the battery in a good condition The charging systems should store a...

Страница 7: ...charger or battery cartridge The battery charger is for charging specific battery pack Never attempt to charge battery pack from other manufacturer s battery cartridge Unsuitable battery cartridges ma...

Страница 8: ...cell Remove fasteners from the magazine on the tool before installing fuel cell Do not depress tool on any surface ground while installing Steps 1 Open the flap 2 Insert the fuel cell make sure the ru...

Страница 9: ...d nail guide 4 To install the magazine first engage the magazine in the slot of the nose piece 5 Push the connecting plate into the handle until it clicks NOTE Do not release the magazine with fastene...

Страница 10: ...tal reuse or connection to power source SYMPTOM 2 Red L E D on charger is blinking Possible reasons Services Battery is hot Remove battery from charger and allow to cool Inspect battery charger and ca...

Страница 11: ...Services Piston positioned wrongly Return piston to original position with a rod or screwdriver O Ring is damaged and causing leakage of gas Contact authorized service agent for repair Damaged valve p...

Страница 12: ...after tool cycles Possible reasons Services Contact arm is bent or tool is dirty Clean tool or replace contact arm as require Possible reasons Services Fuel Cell is low Replace fuel cell according to...

Страница 13: ...stener Dimensions Nail Head Diameter 6 3 mm Nail Length 13 45 mm Shank Diameter 2 6 3 7 mm Applications Steel to Steel 3 0 mm step Steel Plate to Concrete 2 6 3 7 mm Steel Plate to Hard Concrete 3 0 m...

Страница 14: ...14 ICCONS GAS TOOL GT6 IXF USER MANUAL 9 Parts List...

Страница 15: ...SEMBLY FS2 62 18 362 0 HEAD ASSEMBLY FS2 63 01 065 0 SPARK PLUG 64 17 048 0 FUEL NOZZLE 65 01 067 0 MOTOR SLEEVE 66 17 042 0 MOTOR BUMPER M25 POS CODE DESCRIPTION 67 17 043 3 MOTOR M4 68 17 044 0 MOTO...

Страница 16: ...16 ICCONS GAS TOOL GT6 IXF USER MANUAL...

Страница 17: ...onsequential damages resulting from the improper use of the tool The national safety and occupational safety regulations and the safety precautions given in this operating manual must be observed when...

Страница 18: ...MAGE ICCONS ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT If you wish to make a warranty claim then the tool or part must be returned to ICCONS Pty Ltd at the owner s expense ICCON...

Страница 19: ...ctoria 3175 Australia Tel 61 03 9706 4344 Fax 61 03 9768 3329 Email info iccons com au Web www iccons com au This manual must be observed when using the tool All product designations and brand names a...

Страница 20: ......

Отзывы: