background image

Содержание 18180 - to Coil Roofing Nailer

Страница 1: ...TION Read and follow all Safety Rules and Operating Instructions before First Use of this Product Keep this manual with tool Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com cra ftsman 21031 00 Draft 06 09 03 Safety Operation Maintenance Parts List EspaSol ...

Страница 2: ...e maximum system pres sure whichever is greater Do not use a hose swivel connector with this tool Do not pull trigger or depress contact trip while connecting to the air supply as the tool may cycle possibly causing injury When loading tool Do not pull trigger or depress contact trip Do not point the tool at yourself or others Do not place hand or any part of body in the fastener discharge area of...

Страница 3: ...ers Moisture will reduce tool performance and life if not removed from compressed air A fUter regulator lubricator system is required and should be located as close to tool as possible A distance of less than 15 feet is recommended Keep air filter clean A dirty filter will reduce the air pressure to the tool causing a reduction in power and efficiency The air supply system must be able to provide ...

Страница 4: ... Must Be Positioned in Feed Jaw Figure 5 Load Nails Into Feed Jaw Carefully close the magazine cover first Then close the door and secure in position with the latch Make sure the tab in the door holds the magazine cover in place see Figure 6 Figure 6 Close the Magazine Cover and Door NAILING OPERATION Refer to Figures 7 through 9 page 5 WARNING Read and follow all safety rules and operating instru...

Страница 5: ...bounce by holding tool firmly in hand and pressing tool gently against workpiece Let the tool do the work This will allow recoil of tool to bounce tool away from workpiece preventing the driving of second fastener CONTACT TRIP ADJUSTMENT The contact trip may be adjusted up or down to vary the driven depth of the fastener To adjust rotate depth control knob see Figure 7 to raise or lower contract t...

Страница 6: ...procedures to test safety mechanism Leave trigger untouched while pushingcontact trip into workpiece Tool must not fire Pull trigger while contact trip is clear of work and pointed away from operator and others Tool must not fire Depress and hold trigger Push contact trip against work where fastener is needed The tool should drive only one fastener each time the contact trip is pushed against work...

Страница 7: ...d ram 17 Dirty magazine 18 Damaged or worn magazine 1 Check air supply 2 Replace damaged orworn seal or O rings Fig 10 Nos 7 10 11 or 12 3 Replace damaged spring Fig 10 No 8 4 Clean and lubricate cap and head valve Fig 10 Nos 4 and 9 5 Place five or six drops of air tool oil into air inlet cap Fig 10 No 33 1 Check and replace damaged spring Fig 10 No 8 2 Replace damaged or worn O rings Fig 10 Nos ...

Страница 8: ...acement Parts Illustration For Nailer 12 Q 39 90 89 f 21 22 _ _j23 _e J 24 25 _p 26 27 28 i _ _ 29 _ao 6 _ _ 32 34 35 33 48 36 56 59 _ 55 54 53 60 62 _f 64 _ 63 _ 4 qe 67 68 63 47 _ 2 73 53 _ 63 84 45 i _ 83 82 _ J 3 o 74 _ _ 77 63 8 ...

Страница 9: ...82 83 84 85 86 87 88 89 90 91 92 A A 16232 00 17896 00 21047 00 07482 00 21048 00 06349 00 21049 00 16236 60 17445 00 06459 00 06460 00 01434 00 21050 00 16238 00 16239 00 06157 00 16240 00 16244 00 16243 00 16242 00 06748 00 16241 00 16245 00 16246 00 16247 00 16255 00 16256 00 16257 00 16258 00 16259 00 16260 00 16271 00 16261 00 16262 00 16263 00 16264 00 16265 00 16266 00 16267 00 08057 01 162...

Страница 10: ...6xido de carbono gas comprimidode alta presi6no gas embotelladocomofuentes de alimentaci6n para esta herramienta La herramientapodria estallary pro ducirgraves lesiones Nunca conectala herramientaa una presi6nde aire qua pudieraexceder 1379 kPa UtiliceLinicamenteaire regulado limpio y seco que se encuentre dentrode la gama de capaci dad nominalindicadaan la herramienta La herramienta debe eontarco...

Страница 11: ...airs h N P T Longitud 10W Altura 10V Ancho 4 6 Peso 1 90 kg 4 2 Ibs CLAVOS 18413 Clavos galvanizadospara tejado 1 de largo x 0 120 de didmetro 18414 Clavos galvanizados para tsjado 1 de largo x 0 120 de didmetro LINEA DE ABASTEClMIENTO DE AIRE Consulte la Figura 1 sn la p_gina 12 PELIGRO No utilics oxfgeno didxidode carbono gas com primidode alta presidno gas embotelladocomo fuentes de ali mentaci...

Страница 12: ...o gire la cubiertadel dep6sitoparaabrirla v_ase la Figure2 Pestillo de la puerta Tapa Figure 2 Abrlendo el Dep6slto dep6sito El sujetador de olavos deberd estar ajustado a la misma Ion gitud de los clavos que se utilizardn Tire hacia arriba del husillo def sujetador de clavos y gfrelo El indicador de flecha que corresponde al tamaSo de los clavos que se utilizardn deberd estar alineado con la mues...

Страница 13: ...a aplicarse el sujetador Oprima el gatillo para impulsar el sujetador en la plaza de trabajo La herramientapuede operarse ademds sujetandoel gatillo oprimidoy pmsionandoel disparo porcontactocontrala oiezade trabajo Este procedimientobrindaun impulsordpido del sujetador Nunca opera la herramientaa menos que el disparoporcontactohayaentrado en contactocon la pieza de trabajo PRESION DE OPERACION Us...

Страница 14: ... Empareje la punta del ariete con una lima de mano fina y limpia para prolongar la vida I_tildel ariete y de la herramien ta El disparo de sujetadores ser m_ sconsistente si la punta del ariete se mantiene limpia y pareja MECANISMO DE SEGURIDAD Inspeccioneel mecanismo de seguridad de disparo por contacto diariamentepara garantizaruna operaci6ncorrecta No opere la herramientasi el mecanismo no oper...

Страница 15: ...e y cambie los topes daSados Fig 10 No 20 3 Apriete los pernos Fig 10 No 51 1 Revise el abastecimiento de airs 2 Reemplace los anillos O o sello daSados o gastados Fig 10 Nos 7 10 11 b 12 3 Reemplace el resorts daSado Fig 10 No 8 4 Limpie y lubrique la taps y la vdlvula de suministro Fig 10 Nos 4 y 9 5 A_ada de cinco a seis gotas de aceite pars herramientas neumdticas en la taps de la entrada de a...

Страница 16: ...mark TM Trademark suService Mark of Sears Roebuckand Co TM 8M Marca Registrada Mama de FSbrica Marcade Serviciode Sears Roebuck and CO MC MD Marque de commerce Marque ddpos_ e de Sears Roebuckand Co Sears Roebuckand Co ...

Отзывы: