![IBM xSeries 440 8687 Скачать руководство пользователя страница 202](http://html1.mh-extra.com/html/ibm/xseries-440-8687/xseries-440-8687_hardware-maintenance-manual_2037961202.webp)
ServeRAID
error
codes
In
the
following
error
codes,
x
can
be
any
number
or
letter.
Error
code/symptom
FRU/action
1xxx
(Microcode
checksum
error)
v
ServeRAID
controller
2xxx
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3000-31xx
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3200
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3300
(ServeRAID-5i
only)
v
Install
ServeRAID-5i
controller
in
an
extended
PCI
option
slot.
See
the
documentation
that
came
with
the
server
for
more
information.
3E20
(ServeRAID-5i
only)
1.
Remove
the
ServeRAID-5i
controller
from
its
slot
and
install
it
in
the
proper
PCI
option
slot.
2.
Verify
that
the
ServeRAID-5i
controller
is
supported
in
this
server.
3.
ServeRAID-5i
controller.
4.
System
board.
3E2x
1.
Reseat
the
ServeRAID
controller.
2.
Flash
latest
level
of
BIOS
code
and
firmware
for
controller.
3.
ServeRAID-5i
controller.
4.
Integrated
RAID
controller
on
server).
4xxx
thru
5xx
x
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller;
then,
remove
jumpers.
2.
ServeRAID
controller.
6xxx
(Cache
DRAM
error)
(ServeRAID-4H
only)
1.
Reseat
daughter
card.
2.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller;
then,
remove
jumpers.
3.
ServeRAID
controller.
7xxx
thru
8xxx
(Host/local
PCI
bus
interface
error)
1.
Flash
latest
level
of
BIOS
code
and
firmware
for
controller.
2.
If
ServeRAID-4x
controller,
replace
controller.
3.
If
ServeRAID-5i
controller,
integrated
RAID
controller
on
the
server.
190
xSeries
440
Type
8687:
Hardware
Maintenance
Manual
Содержание xSeries 440 8687
Страница 1: ...xSeries 440 Type 8687 Hardware Maintenance Manual ERserver...
Страница 2: ......
Страница 3: ...xSeries 440 Type 8687 Hardware Maintenance Manual ERserver...
Страница 6: ...iv xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 12: ...x xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 26: ...14 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 62: ...50 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 80: ...68 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 162: ...150 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 206: ...194 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 210: ...Figure A 1 2 4 5 6 7 8 9 9 3 10 198 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 223: ...Related service information 211...
Страница 224: ...212 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 225: ...Related service information 213...
Страница 226: ...214 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 227: ...Related service information 215...
Страница 228: ...216 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 229: ...Related service information 217...
Страница 230: ...218 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 240: ...228 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 241: ...Related service information 229...
Страница 242: ...230 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 243: ...Related service information 231...
Страница 250: ...238 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 256: ...244 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 257: ......
Страница 258: ...Part Number 4949 49Y0156 1P P N 24P2935...