Error
code/symptom
FRU/action
201-XXX-Y24
(Multiple
DIMM
failure
in
Port
1
Bank
4;
see
Note:
Y
=
SMP
Board
[0=Bottom
SMP
Board;
1=Top
SMP
Board]
1.
Isolate
failing
DIMM:
a.
Replace
a
DIMM
in
bank
with
a
″
known
good
″
DIMM.
b.
Rerun
memory
diagnostic
for
the
failing
bank
on
failing
SMP
Board.
c.
If
test
fails,
mark
replaced
DIMM
as
″
good
″
DIMM.
d.
If
test
passes,
mark
replaced
DIMM
as
″
bad
″
DIMM.
e.
If
DIMM
tested
is
″
bad
″
,
remove
it
and
replace
it.
f.
If
DIMM
tested
is
″
good
″
,
do
not
replace
it.
2.
Repeat
steps
through
with
other
DIMMs
in
failing
bank
until
error
is
fixed.
3.
If
error
is
not
fixed,
replace
SMP
Board
Y.
201-XXX-Y31
(Multiple
DIMM
failure
in
Port
2
Bank
1;
see
Note:
Y
=
SMP
Board
[0=Bottom
SMP
Board;
1=Top
SMP
Board]
1.
Isolate
failing
DIMM:
a.
Replace
a
DIMM
in
bank
with
a
″
known
good
″
DIMM.
b.
Rerun
memory
diagnostic
for
the
failing
bank
on
failing
SMP
Board.
c.
If
test
fails,
mark
replaced
DIMM
as
″
good
″
DIMM.
d.
If
test
passes,
mark
replaced
DIMM
as
″
bad
″
DIMM.
e.
If
DIMM
tested
is
″
bad
″
,
remove
it
and
replace
it.
f.
If
DIMM
tested
is
″
good
″
,
do
not
replace
it.
2.
Repeat
steps
through
with
other
DIMMs
in
failing
bank
until
error
is
fixed.
3.
If
error
is
not
fixed,
replace
SMP
Board
Y.
201-XXX-Y32
(Multiple
DIMM
failure
in
Port
2
Bank
2;
see
Note:
Y
=
SMP
Board
[0=Bottom
SMP
Board;
1=Top
SMP
Board]
1.
Isolate
failing
DIMM:
a.
Replace
a
DIMM
in
bank
with
a
″
known
good
″
DIMM.
b.
Rerun
memory
diagnostic
for
the
failing
bank
on
failing
SMP
Board.
c.
If
test
fails,
mark
replaced
DIMM
as
″
good
″
DIMM.
d.
If
test
passes,
mark
replaced
DIMM
as
″
bad
″
DIMM.
e.
If
DIMM
tested
is
″
bad
″
,
remove
it
and
replace
it.
f.
If
DIMM
tested
is
″
good
″
,
do
not
replace
it.
2.
Repeat
steps
through
with
other
DIMMs
in
failing
bank
until
error
is
fixed.
3.
If
error
is
not
fixed,
replace
SMP
Board
Y.
201-XXX-Y33
(Multiple
DIMM
failure
in
Port
2
Bank
3;
see
Note:
Y
=
SMP
Board
[0=Bottom
SMP
Board;
1=Top
SMP
Board]
1.
Isolate
failing
DIMM:
a.
Replace
a
DIMM
in
bank
with
a
″
known
good
″
DIMM.
b.
Rerun
memory
diagnostic
for
the
failing
bank
on
failing
SMP
Board.
c.
If
test
fails,
mark
replaced
DIMM
as
″
good
″
DIMM.
d.
If
test
passes,
mark
replaced
DIMM
as
″
bad
″
DIMM.
e.
If
DIMM
tested
is
″
bad
″
,
remove
it
and
replace
it.
f.
If
DIMM
tested
is
″
good
″
,
do
not
replace
it.
2.
Repeat
steps
through
with
other
DIMMs
in
failing
bank
until
error
is
fixed.
3.
If
error
is
not
fixed,
replace
SMP
Board
Y.
Symptom-to-FRU
index
171
Содержание xSeries 440 8687
Страница 1: ...xSeries 440 Type 8687 Hardware Maintenance Manual ERserver...
Страница 2: ......
Страница 3: ...xSeries 440 Type 8687 Hardware Maintenance Manual ERserver...
Страница 6: ...iv xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 12: ...x xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 26: ...14 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 62: ...50 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 80: ...68 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 162: ...150 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 206: ...194 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 210: ...Figure A 1 2 4 5 6 7 8 9 9 3 10 198 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 223: ...Related service information 211...
Страница 224: ...212 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 225: ...Related service information 213...
Страница 226: ...214 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 227: ...Related service information 215...
Страница 228: ...216 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 229: ...Related service information 217...
Страница 230: ...218 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 240: ...228 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 241: ...Related service information 229...
Страница 242: ...230 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 243: ...Related service information 231...
Страница 250: ...238 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 256: ...244 xSeries 440 Type 8687 Hardware Maintenance Manual...
Страница 257: ......
Страница 258: ...Part Number 4949 49Y0156 1P P N 24P2935...