POST
and
SMI
error
messages
BIOS
can
log
two
types
of
error
messages
in
the
BMC
log
and
the
system-error
log:
POST
events,
which
occur
during
system
startup,
and
SMI
events,
which
are
generally
run
time
errors
detected
by
hardware.
The
following
table
describes
the
possible
POST
and
SMI
error
messages
and
suggested
actions
to
correct
the
detected
problems.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
message
Action
POST
reporting
Processor
Event:
Invalid
configuration
of
processor
card.
Chassis
Number
=
X.
Make
sure
that
all
microprocessors
have
the
same
part
number.
POST
reporting
Processor
Event:
Processor
mismatch
detected.
Chassis
Number
=
X.
Processor
Number
=
Y.
1.
Make
sure
that
the
BIOS
code
is
at
the
latest
level.
2.
Make
sure
that
all
microprocessors
have
the
same
part
number.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
POST
reporting
Processor
Event:
POST
does
not
support
current
stepping
of
processor.
Chassis
Number
=
X,
Processor
Number
=
Y.
1.
Make
sure
that
the
BIOS
code
is
at
the
latest
level.
2.
Make
sure
that
all
microprocessors
have
the
same
part
number.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
POST
reporting
Processor
Event:
Unable
to
apply
microcode
(patch)
update.
Chassis
Number
=
X.
Processor
Number
=
Y.
(Trained
service
technician
only)
Replace
the
microprocessor.
POST
reporting
Processor
Event:
Processor
failed
BIST.
Chassis
Number=
X.
Processor
Number
=
Y.
(Trained
service
technician
only)
Replace
the
microprocessor.
POST
reporting
memory
event:
North
Bridge
Uncorrectable
memory
error
occurred.
Chassis
Number
=
X.
Memory
Card
=
Y.
Memory
DIMM
=
Z.
1.
Reseat
the
DIMM.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
POST
reporting
memory
event:
North
Bridge
Correctable
memory
threshold
occurred.
Chassis
Number
=
X.
Memory
Card
=
Y.
Memory
DIMM
=
Z.
Failing
Symbol
=
0xcb.
1.
Reseat
the
DIMM.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
POST
reporting
memory
event:
DIMM
Disabled
-
Failed
ECC
Test.
Chassis
Number
=
X.
Memory
Card
=
Y.
Memory
DIMM
=
Z.
1.
Reseat
the
DIMM.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
34
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Содержание xSeries 366
Страница 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 181: ...V video connector 6 VRM LED 64 W Web site 1 weight 3 World Wide Web 1 Index 165...
Страница 182: ...166 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 183: ......
Страница 184: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...