Hot-swap fan 1
Hot-swap fan 5
Hot-swap fan 6
Hot-swap fan 7
Hot-swap fan 8
Fan error
LED
Hot-swap fan 2
Hot-swap fan 3
Hot-swap fan 4
1.
Read
the
safety
information
that
begins
on
page
vii,
and
Attention:
Static
electricity
that
is
released
to
internal
server
components
when
the
server
is
powered-on
might
cause
the
server
to
halt,
which
could
result
in
the
loss
of
data.
To
avoid
this
potential
problem,
always
use
an
electrostatic-discharge
wrist
strap
or
other
grounding
system
when
working
inside
the
server
with
the
power
on.
2.
Remove
the
top
cover
(see
Attention:
To
ensure
proper
system
cooling,
do
not
leave
the
top
cover
off
the
server
for
more
than
2
minutes.
3.
Open
the
fan-locking
handle
by
sliding
the
orange
release
latch
in
the
direction
of
the
arrow.
4.
Pull
upward
on
the
free
end
of
the
handle
to
lift
the
fan
out
of
the
server.
To
install
a
hot-swap
fan,
complete
the
following
steps:
1.
Open
the
fan-locking
handle
on
the
replacement
fan.
2.
Lower
the
fan
into
the
socket,
and
close
the
handle
to
the
locked
position.
3.
Replace
the
top
cover.
Chapter
4.
Removing
and
replacing
server
components
117
Содержание xSeries 366
Страница 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 181: ...V video connector 6 VRM LED 64 W Web site 1 weight 3 World Wide Web 1 Index 165...
Страница 182: ...166 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 183: ......
Страница 184: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...